MCP3909RD-1PH1 Microchip Technology, MCP3909RD-1PH1 Datasheet - Page 33

BOARD DES MCP3909 ENERGY METER

MCP3909RD-1PH1

Manufacturer Part Number
MCP3909RD-1PH1
Description
BOARD DES MCP3909 ENERGY METER
Manufacturer
Microchip Technology

Specifications of MCP3909RD-1PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
MCP3909, PIC18F85J90
Primary Attributes
Single Phase Shunt Energy Meter
Secondary Attributes
16 Bit ADC
Ic Function
Single Phase Energy Measurement IC
Supply Voltage Range
4.5V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SSOP
No. Of Pins
24
Interface Type
SPI
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5.1
© 2009 Microchip Technology Inc.
CALIBRATION OVERVIEW
The method to calculate the values for the calibration registers in “Chapter
3. “PIC18F85J90 Calculation and Register Description” are described in this
chapter. These registers are used to remove offset, set gain and phase adjustments,
and include (units)/LSB adjustments for the meter outputs. The calibration flow charts
and equations presented in this section are all automated using Microchip’s “Single
Phase Energy Meter Calibration Software”, downloadable from Microchip’s energy
metering web site. The following calibration routines are described in this chapter.
• Active Power Calibration
• RMS Current and Voltage Calibration
• Apparent Power Calibration
The method of calibrating these three separate signal flows can be combined into
4 different calibration configurations. These configurations consist of supplying specific
voltages and currents at specific phase angles to the meter during calibration.
Depending on the accuracy and meter type, not all 4 calibration configurations are
required to fully calibrate a meter. In some cases only a single point calibraton is
required. The software allows individual configurations to be turned on or off when
going through the calibration flow.