Main Purpose
Power Management, Power Supply Supervisor/Tracker/Sequencer
Utilized Ic / Part
MAX16046, MAX16048
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
GPIO6 is configurable as an active-low MARGIN input.
Drive MARGIN low before varying system voltages above
or below the thresholds to avoid signaling an error. Drive
MARGIN high for normal operation.
When MARGIN is pulled low or r4Dh[1] is a ‘1,’ the mar-
gin function is enabled. FAULT1, FAULT2, Any_Fault,
and RESET are latched in their current state. Threshold
violations will be ignored, and faults will not be logged.
GPIO4 is configurable to act as an active-low manual
reset input, MR. Drive MR low to assert RESET. RESET
remains low for the selected reset timeout period after
MR transitions from low to high. See the RESET section
for more information on selecting a reset timeout period.
Set r1Eh[1:0] and register r1Dh[7] to ‘110’ to configure
GPIO6 as WDO. Set r1Dh[6:4] to ‘111’ to configure
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Table 9. EN_OUT1–EN_OUT12 Configuration
26
EEPROM ADDRESS
______________________________________________________________________________________
REGISTER/
1Fh
Watchdog Input (WDI) and Output (WDO)
RANGE
[2:0]
[5:3]
[7:6]
BIT
Manual Reset (MR)
EN_OUT1 Configuration:
000 = EN_OUT1 is an open-drain active-low output
001 = EN_OUT1 is an open-drain active-high output
010 = EN_OUT1 is a push-pull active-low output
011 = EN_OUT1 is a push-pull active-high output
100 = EN_OUT1 is used in closed-loop tracking
101 = EN_OUT1 is configured with a charge-pump output (MON1 + 5V) capable of
driving an external n-channel MOSFET
110 = Reserved
111 = Reserved
EN_OUT2 Configuration:
000 = EN_OUT2 is an open-drain active-low output
001 = EN_OUT2 is an open-drain active-high output
010 = EN_OUT2 is a push-pull active-low output
011 = EN_OUT2 is a push-pull active-high output
100 = EN_OUT2 is used in closed-loop tracking
101 = EN_OUT2 is configured with a charge-pump output (MON2 + 5V) capable of
driving an external n-channel MOSFET
110 = Reserved
111 = Reserved
EN_OUT3 Configuration (LSBs):
000 = EN_OUT3 is an open-drain active-low output
001 = EN_OUT3 is an open-drain active-high output
010 = EN_OUT3 is a push-pull active-low output
011 = EN_OUT3 is a push-pull active-high output
100 = EN_OUT3 is used in closed-loop tracking
101 = EN_OUT3 is configured with a charge-pump output (MON3 + 5V) capable of
driving an external n-channel MOSFET
110 = Reserved
111 = Reserved
MARGIN
GPIO5 as WDI. WDO is an open-drain active-low output.
See the Watchdog Timer section for more information
about the operation of the watchdog timer.
The MAX16046 includes twelve programmable outputs,
and the MAX16048 includes eight programmable out-
puts. These outputs are capable of connecting to either
the enable (EN) inputs of a DC-DC or LDO power supply
or to the gates of series-pass MOSFETs for closed-loop
tracking mode, or for charge-pump mode. Selectable out-
put configurations include: active-low or active-high,
open-drain or push-pull. EN_OUT1–EN_OUT4 are also
configurable for closed-loop tracking, and EN_OUT1–
EN_OUT6 can act as charge-pump outputs with no
closed-loop tracking. Use the registers r1Fh to r22h to
configure outputs. See Table 9 for detailed information on
configuring EN_OUT1–EN_OUT12.