CDB4385 Cirrus Logic Inc, CDB4385 Datasheet - Page 42

BOARD EVAL FOR CS4385 DAC

CDB4385

Manufacturer Part Number
CDB4385
Description
BOARD EVAL FOR CS4385 DAC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB4385

Number Of Dac's
8
Number Of Bits
24
Outputs And Type
8, Differential
Sampling Rate (per Second)
192k
Data Interface
Serial
Dac Type
Voltage
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CDB4385
Description/function
Audio D/A
Operating Supply Voltage
5 V
Product
Audio Modules
For Use With/related Products
CS4385
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1154
42
6.7.2 Channel A Volume = Channel B Volume (Px_A=B)
6.7.3 Single Volume Control (SNGLVOL)
6.8
6.8.1 Soft Ramp and Zero Cross CONTROL (SZC)
SZC1
1
7
Ramp and Mute (address 08h)
Default = 0
0 - Disabled
1 - Enabled
Function:
The AOUTAx and AOUTBx volume levels are independently controlled by the A and the B Channel Vol-
ume Control Bytes when this function is disabled. The volume on both AOUTAx and AOUTBx are deter-
mined by the A Channel Attenuation and Volume Control Bytes (per A-B pair), and the B Channel Bytes
are ignored when this function is enabled.
Default = 0
0 - Disabled
1 - Enabled
Function:
The individual channel volume levels are independently controlled by their respective Volume Control
Bytes when this function is disabled. The volume on all channels is determined by the A1 Channel Volume
Control Byte, and the other Volume Control Bytes are ignored when this function is enabled.
Default = 10
00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp on Zero Crossings
Function:
Immediate Change
When Immediate Change is selected, all level changes will take effect immediately in one step.
Zero Cross
Zero Cross Enable dictates that signal-level changes, either by attenuation changes or muting, will occur
on a signal zero crossing to minimize audible artifacts. The requested level change will occur after a tim-
eout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample rate) if the signal
does not encounter a zero crossing. The zero cross function is independently monitored and implemented
for each channel.
Soft Ramp
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally ramp-
ing, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock periods.
SZC0
6
0
RMP_UP
5
1
RMP_DN
1
4
PAMUTE
3
1
DAMUTE
2
1
MUTE_P1
0
1
MUTE_P0
CS4385
DS671F2
0
0

Related parts for CDB4385