EVAL-AD7147EBZ Analog Devices Inc, EVAL-AD7147EBZ Datasheet - Page 47

BOARD EVAL FOR AD7147ACPZ

EVAL-AD7147EBZ

Manufacturer Part Number
EVAL-AD7147EBZ
Description
BOARD EVAL FOR AD7147ACPZ
Manufacturer
Analog Devices Inc
Series
CapTouch™r

Specifications of EVAL-AD7147EBZ

Sensor Type
Touch, Capacitive
Interface
SPI Serial
Voltage - Supply
2.6 V ~ 3.6 V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
AD7147
Silicon Manufacturer
Analog Devices
Application Sub Type
CapTouch Controller
Kit Application Type
Data Converter
Silicon Core Number
AD7147
Kit Contents
CapTouch Evaluation Board, USB Cable
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Compliant
Table 27. STAGE_COMPLETE_INT_ENABLE Register
Address
0x007
Data Bit
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[15:13]
Default
Value
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Type
Name
STAGE0_COMPLETE_INT_ENABLE
STAGE1_COMPLETE_INT_ENABLE
STAGE2_COMPLETE_INT_ENABLE
STAGE3_COMPLETE_INT_ENABLE
STAGE4_COMPLETE_INT_ENABLE
STAGE5_COMPLETE_INT_ENABLE
STAGE6_COMPLETE_INT_ENABLE
STAGE7_COMPLETE_INT_ENABLE
STAGE8_COMPLETE_INT_ENABLE
STAGE9_COMPLETE_INT_ENABLE
STAGE10_COMPLETE_INT_ENABLE
STAGE11_COMPLETE_INT_ENABLE
GPIO_INT_ENABLE
Unused
Rev. B | Page 47 of 72
Description
STAGE0 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE0 conversion
STAGE1 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE1 conversion
STAGE2 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE2 conversion
STAGE3 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE3 conversion
STAGE4 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE4 conversion
STAGE5 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE5 conversion
STAGE6 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE6 conversion
STAGE7 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE7 conversion
STAGE8 conversion complete interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE8 conversion
STAGE9 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE9 conversion
STAGE10 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE10 conversion
STAGE11 conversion interrupt control
0 = interrupt source disabled
1 = INT asserted at completion of STAGE11 conversion
Interrupt control when GPIO input pin changes level
0 = disabled
1 = enabled
Set to 0