CYCLONEMAX Freescale Semiconductor, CYCLONEMAX Datasheet - Page 30

CYCLONE MAX FLASH PROGRAM

CYCLONEMAX

Manufacturer Part Number
CYCLONEMAX
Description
CYCLONE MAX FLASH PROGRAM
Manufacturer
Freescale Semiconductor
Series
ColdFire®r
Type
FLASHr
Datasheets

Specifications of CYCLONEMAX

Contents
Programmer/Debugger
Positions/sockets
1
Description/function
Programmer, Debugger
Silicon Family Name
MPC5xx
Core Architecture
Coldfire, Power Architecture
Core Sub-architecture
Coldfire V2, Power Architecture
Rohs Compliant
Yes
For Use With/related Products
MPC5xx / 55xx
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CYCLONEMAX
Manufacturer:
FREESCALE
Quantity:
20 000
4.2
4.3
4.4
4.5
26
BDM Shift Clock Delay Constant
Specify Programming Algorithm and S-Record
Base Address
Script Wizard
The BDM Shift Clock Delay Constant allows the user to set the BDM shift
clock speed of the Cyclone MAX. The equation for determining the shifting
frequency is: 50000000 / (5 + 2*n). This clock cannot generally exceed a div 6
of the processor bus frequency.
To specify the programming algorithm for the target, the user may simply
select the CM (Choose Module) command from the Programming Sequence
list (1) and add it to the programming steps (2) using the add button (3).
Similarly, to specify the S-Record to be programmed into the target, the user
may simply select the SS (Specify S-Record) command from the
Programming Sequence list (1) and add it to the programming steps (2) using
the add button (3).
See Figure 2-1 for a visual reference.
Depending on the programming algorithm, the user may be required to enter
the base address for the module. If the programming algorithm requires a
base address, the Module Base Address Settings will be displayed. The user
must enter the correct base address. Otherwise, the default value (0) shown
in the diagram will be used.
The Script Wizard is a convenient addition to the Cyclone Image Creation
Utility. The Script Wizard allows the user to simply select the programming
functions to be executed. The Script Wizard then orders these functions
automatically.
To begin, click the Launch Script Wizard button on the right side of the
Cyclone Image Creation Utility. This opens the Script Wizard.
CYCLONE MAX
Cyclone MAX User Manual

Related parts for CYCLONEMAX