PC4701U Renesas Electronics America, PC4701U Datasheet - Page 19

no-image

PC4701U

Manufacturer Part Number
PC4701U
Description
EMULATOR BASE UNIT
Manufacturer
Renesas Electronics America
Type
Microcontrollerr
Datasheet

Specifications of PC4701U

Contents
PC4701U Emulator, Cables, User Manual and CD-ROM
For Use With/related Products
M16C Family, 7700 Family, 740 Family
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2.3 Specifications
Table 2.1 lists the specifications of the emulator PC4701U. Supported debugging functions vary
according to the emulator debuggers.
Table 2.1 Specifications
* For details about external dimensions, refer to "7.2 External Dimensions" (P.46).
Applicable MCUs
Software break
Hardware break
Hardware break condition
Exception event detection
Real-time trace
Real-time RAM monitor
Time measurement
C0 coverage
Event output
External trace signal input
Host computer Interface LAN
Connection to target system
AC supply voltage for emulator unit
Power consumption
External dimensions *
Weight
Operating environmental
conditions
Storage environmental
conditions
Overseas standards
Temperature
Humidity
Dust and dirt
Temperature
Humidity
Dust and dirt
USB
LPT parallel
Width
Depth
Height
( 17 / 48 )
M16C Family (32/16- and 16-bit)
7700 Family (16-bit)
740 Family (8-bit)
64 points
6 points (Bus detection / Interrupt / External trace signal)
AND / OR / State transition
Access protect
• Trace range: 32K cycles.
• Trace data: Bus, 8-bit external trace signal, 40-bit time stamp.
• Five trace modes: Break/Before/About/After/Full
• Can be recorded ON/OFF by events.
• Can be used for performance analysis and overhead measurement.
1024 bytes (Data / Access or not / Final access result)
• Execution time between program start to stop.
• Maximum/minimum/average execution time and pass count of
• Count clock : Equal to MCU Clock or 16 MHz
256 KB
• Break signals: one point
• Event signals: 6 points
TTL level: 8 points
10BASE-T
USB 1.1, full-speed
ECP, EPP, Byte/compatibility and Nibble/compatibility modes
Via an emulation pod (option), connected to the target. (For de-
tails, refer to data sheets of emulation pods.)
Built-in. Converted automatically.
100 V to 120 V AC (50/60 Hz), 200 V to 240 V AC (50/60 Hz).
66 W maximum
112 mm
242 mm
197 mm
2.7 kg
5° to 35°C
20% to 80% (non-condensing)
General office environment
-10° to 60°C
0% to 90% (non-condensing)
General office environment
• US Safety Standards (UL1950), also applied in Canada
• US EMI Standards (FCC part 15 Class A)
• CE marking (EN60950, EN55022, EN55024, EN61000-3-2)
specified four zones.