Table 3.7 Conditions to Be Set (cont)
Notes: 1. After the sequential condition and the count specification condition of Event Condition 1
Classification
[Ch1, 2, 3] list box
(cont)
[Ch4, 5] list box
2. If a reset point is satisfied, the satisfaction of the condition set in Event Condition will be
3. If the start condition is satisfied after the end condition of the performance
4. If the start condition is satisfied after the end condition has been satisfied by the point-
have been set, break and trace acquisition will be halted if the sequential condition is
satisfied for the specified count.
disabled. For example, if the condition is satisfied in the order of Event Condition 3, 2,
reset point, 1, the break or trace acquisition will not be halted. If the condition is
satisfied in the order of Event Condition 3, 2, reset point, 3, 2, 1, the break and trace
acquisition will be halted.
measurement has been satisfied, performance measurement will be restarted. For the
measurement result after a break, the measurement results during performance
measurement are added.
to-point of the internal trace, trace acquisition will be restarted.
Item
Ch2 to Ch1 PA
Ch1 to Ch2 PA
Sets the point-to-point of the internal trace (the start or end condition of
trace acquisition) using Event Conditions 4 and 5.
Don’t care
I-Trace: Ch5 to Ch4
PtoP
I-Trace: Ch5 to Ch4
PtoP, Power-on reset
Description
Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 2 (start condition) to the
satisfaction of the condition set in Event Condition
1 (end condition).
Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 1 (start condition) to the
satisfaction of the condition set in Event Condition
2 (end condition).
Sets no start or end condition of trace acquisition.
Sets the acquisition period during the time from the
satisfaction of the condition set in Event Condition
5 (start condition) to the satisfaction of the
condition set in Event Condition 4 (end condition).
Sets the acquisition period during the time from the
satisfaction of the condition set in Event Condition
5 (start condition) to the satisfaction of the
condition set in Event Condition 4 (end condition)
or the power-on reset.