AD9956-VCO/PCB Analog Devices Inc, AD9956-VCO/PCB Datasheet - Page 4

no-image

AD9956-VCO/PCB

Manufacturer Part Number
AD9956-VCO/PCB
Description
BOARD EVAL 14BIT 1.8V 48LFCSP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of AD9956-VCO/PCB

Module/board Type
Evaluation Board
For Use With/related Products
AD9956
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
AD9956/PCB
SOFTWARE
SETUP
To install the software on the your PC:
1.
2.
3.
4.
Insert the AD9956/PCB evaluation software CD-ROM into
the CD-ROM drive.
Use Windows Explorer to navigate to the CD-ROM drive.
The folders at the root level are labeled Datashts,
DDS_Tut, Instruct, Layout, Schematic, and Software.
The Datashts folder contains the data sheet for the
AD9956. DDS_Tut contains the DDS tutorial. Instruct
contains the evaluation board software and hardware
instructions (this document). Layout contains the PCB
layout files for the evaluation board. Software contains the
setup.exe file for the evaluation software and the file
install.pdf.
Read install.pdf completely and then follow the instruc-
tions in this file to install the software on your PC.
Figure 2. AD9956/PCB Evaluation Board Software Status Message upon Successful Load
Rev. 0 | Page 4 of 12
RUNNING AND USING THE SOFTWARE
To launch the evaluation software:
1.
2.
Three dialog boxes are automatically loaded: Control, Profile,
and DUT Signals. You can load other dialog boxes from the
View menu. You can also program the registers of the device
directly from the Debug Window, which you can access from
the View menu.
At startup, the software searches for the presence of a function-
ing AD9956 evaluation board. If it detects the evaluation board,
a green splash screen appears, as shown in Figure 2. If it fails to
detect a working part, a red error message is displayed.
Find the executable, AD9956v.exe, in the following folder:
c:\Program Files\ADI\AD9956 Evaluation Software
Double-click the icon to launch the evaluation software. A
status window similar to Figure 2 appears in the center of
the AD9956 Evaluation Software dialog box as progress is
made in loading the evaluation software (a black window
with green text). If the software loads successfully, the text
remains green and the “software up and running” message
is displayed. If the loading fails, the text turns red, and a
message describing the failure is displayed.

Related parts for AD9956-VCO/PCB