Specifications of RTA-FOUSB-MON

Contents
USB Compact Flash Programmer, USB Cable, CD-ROM and User Manual
For Use With/related Products
M16C Family and 740 Family
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Firmware versions and loaded
MCU Monitor Image (MMI) file
An example of the FoUSB Programmer application with the SKP16C62P board connected is shown
below.
Basic FoUSB Programmer Operations
The Standard Device Programmer Functions follow the basic file open, erase, program, ROM memory
dump, and RAM memory read/write like other programmers.
The Unlock function used to “unlock” Renesas MCU’s for memory access. Renesas M16C MCU’s are
equipped with a security feature, a 7-byte ID, to prevent firmware program disassembly. The user must
enter the security ID information to be able to access Flash memory access. In a ‘Locked’ state, the only
function you can use is the Unlock function.
An exception of the Unlock function is when the security ID is all zeroes (0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00) or all ones (0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF). For these two ID’s, the application
automatically unlocks the device.
The Command button is used to send boot commands to the target MCU (when in boot mode). This
button is used to debug monitor firmware and by device programmer manufacturers.
RTA-FOUSB-MON User’s Manual Rev 2.2
Open allows you to select a firmware file you want to program to the target MCU.
Read allows you to dump Flash memory and display it on a screen or write to a text file.
Erase allows you to erase a block or the entire Flash memory.
Memory allows you to read or write internal RAM memory including MCU SFRs.
Program allows you to program or erase, program, and verify the target MCU.
Fig. 5.2 Example of FoUSB Programmer Screen
with Target Connected
7 / 27
Applications Engineering
Jan 2005