Y92F-30 Omron, Y92F-30 Datasheet - Page 15

ADAPTER PANEL MNT FOR H3CR/H5CX

Y92F-30

Manufacturer Part Number
Y92F-30
Description
ADAPTER PANEL MNT FOR H3CR/H5CX
Manufacturer
Omron
Type
Panel Mounting Adaptersr
Datasheets

Specifications of Y92F-30

Accessory Type
Panel Mount Adapter, Frame
Mounting Type
Panel Mount
Rohs Compliant
Yes
Length
58 mm
Mounting Hole Size
45 mm
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACZ2998 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ2382 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F30
Z885
Precautions
H5CR
• The input circuit is not isolated from the power supply circuit.
• If power is interrupted for less than 10 ms, operation will
• Connect the power supply voltage through a relay or switch
• Depending on switching frequency, current surges may
• Do not use external sources to increase the voltage of input
• Be sure that the load of the control output (contact, transistor)
• The transistor output is opto-isolated from the internal
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
1-800-55-OMRON
Cat. No. GC TMCN1
• The following displays will appear if an error occurs. The
The internal circuit might be damaged by a surrounding AC
circuit, so use an isolated AC power supply with equipment
connected to the input circuit.
continue normally. If power is interrupted for 10 to 500 ms,
operation will be inconsistent, and timing may stop or reset,
depending on the mode.
in such a way that the voltage reaches a fixed value
immediately.
degrade relay contacts; relays with a capacity greater than
10 A are recommended.
signals (control signal, reset, gate, and key protection).
is less than the maximum values indicated in the
specifications. If the output load exceeds the recommended
value, the life span of the contact output type will be
shortened dramatically, and the transistor of the transistor
output type will be damaged.
circuitry, so either NPN or PNP transistors can be used.
Display
present value and output enter the same status as after
pressing the RESET key.
POWER SUPPLIES
INPUT AND OUTPUT
SELF-DIAGNOSTIC FUNCTION
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
Error
CPU
Memory
Output
status
OFF
3/02
Correction
Press
RESET
key
Set
No
change
Set at the
factory
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
Specifications subject to change without notice.
15
• The timer set value can be changed while the timer is
• To avoid changing the output when changing the set value, it
• When using the timer in an area with much electrical noise,
• Organic solvents (such as paint thinner), as well as very
• When the timer is installed in a control box and tests are
This product contains a lithium battery. Lithium batteries
explode if incinerated. Dispose of the digital timer as a
combustible item.
operating, so a high value can be set temporarily to
inactivate the timer, or a low value can be set to activate the
timer more quickly. If the set value is changed accidentally
during operation, the timed output might be activated.
Therefore, turn the key protection input ON unless the set
value is being changed.
is recommended to begin changing the set value by entering
a large number in the higher digit.
separate the timer, wiring, and the equipment which
generates the input signals as far as possible from the noise
sources. It is also recommended to shield the input signal
wiring to prevent electrical interference.
acidic or basic solutions, might damage the outer casing of
the timer.
conducted which may damage the timer's internal circuitry
(for example, a test measuring the maximum voltage
difference between the control circuit and metal
components), remove the timer from the control box or short
circuit the terminals.
CHANGING SET VALUES
OPERATING ENVIRONMENT
MAXIMUM VOLTAGE TEST
CAUTION
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
Printed in the U.S.A.