HC2-HP-DC24V-F Panasonic Electric Works, HC2-HP-DC24V-F Datasheet

no-image

HC2-HP-DC24V-F

Manufacturer Part Number
HC2-HP-DC24V-F
Description
RELAY PWR 7A DPDT 24VDC AMB PCB
Manufacturer
Panasonic Electric Works
Series
HCr
Datasheets

Specifications of HC2-HP-DC24V-F

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
37mA
Coil Voltage
24VDC
Turn On Voltage (max)
19.2 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
7A @ 250VAC
Control On Voltage (max)
19.2 VDC
Control Off Voltage (min)
2.4 VDC
Brand/series
HC Series
Current, Rating
7 A
Function
General Purpose
Power, Rating
1750 VA
Standards
UL, CSA, VDE
Termination
Solder
Voltage, Control
24 VDC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2762
mm
SPECIFICATIONS
Contacts
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
Expected life (min. operations)
Electrical (at 20 cpm)
Arrangement
Initial current resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive)
Nominal operating power
1
2
3
4
Mechanical life (at 180 cpm)
Detection current: 10 mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
and desired reliability level, therefore it is recommended to check this with the
actual load.
(1 Form C)
(2 Form C)
(3 Form C)
(4 Form C)
inch
HC1
HC2
HC3
HC4
20.8
.819
Nominal
switching capacity
Max. switching
power
Max. switching
voltage
Max. switching
current
Min. switching
capacity
Voltage
Load
#1
Current
Current
Current
Current
27.2
1.071
35.2
1.386
1 Form C 2 Form C 3 Form C
250 V AC
2,500 VA 1,750 VA 1,750 VA
AC (50Hz): 1.3VA, AC (60Hz): 1.2 VA
10 A
10 A
Gold-flashed silver alloy
(cos
Resistive
10A
7A
5A
7A
5A
3A
7A
5A
5A
3A
2A
250 V AC
= 1)
DC:0.9 to 1.1W
20.8
.819
7 A
7 A
125 V AC
1 mA, 1 V DC
MINIATURE RELAY FOR
250 V AC
WIDER APPLICATIONS
30 m
(cos
250 V AC
Inductive
HCE Amber Relays
7 A
7 A
3.5A
2.5A
1.5A
3.5A
0.5A
5A
3A
2A
2A
1A
] 0.4)
27.2
1.071
silver nickel
35.2
1.386
Gold-clad
250 V AC
4 Form C
1,250 VA
5 A
5 A
(cos
Resistive
10A
7A
5A
7A
5A
3A
7A
5A
5A
3A
2A
= 1)
DC type: 10
FEATURES
• Extra long life — Min. 10
• 4 contact arrangements
4 Form C (for 5 A 250 V AC),
3 Form C (for 7 A 250 V AC),
2 Form C (for 7 A 250 V AC),
1 Form C (for 10 A 250 V AC)
• Applicable to low to high level loads (100µA to 10A)
• Amber sealed types available
• Bifurcated contact types available as HC4D
Characteristics
*
*
250 V AC
Max. operating speed
Initial insulation resistance
Initial
breakdown
voltage*
Operate time*
(at 20°C)
Release time (without diode)*
(at nominal voltage) (at 20°C)
Temperature rise, max. (at 70 C)
(at nominal voltage)
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
5
6
Detection time: 10 s
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
(cos
Inductive
1
8
2.5A
1.5A
1.5A
0.8A
0.4A
, AC type: 5 10
3A
2A
1A
2A
1A
] 0.4)
Between open contacts
Between contact sets
Between contact and coil
2
(at nominal voltage)
HC RELAYS
6
Resistive
7
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.
Humidity
3A
3A
3A
3A
2
8
mechanical operations (DC type)
30 V DC
3
5
4
Inductive
Min. 1,000 MW at 500 V DC
0.6A
0.4A
0.4A
1A
20 cpm (at max. rating)
Min. 980 m/s
2,000 Vrms for 1 min.
10 to 55 Hz at double
10 to 55 Hz at double
Min. 196 m/s
Approx. 30g
700 Vrms for 1 min.
700 Vrms for 1 min.
amplitude of 1 mm
amplitude of 2 mm
–58 F to +158 F
–50 C to +70 C
(DC, AC type)
(DC, AC type)
5 to 85% R.H.
Max. 20 ms
Max. 20 ms
80 C
Expected life
2
2
1.06 oz
{100 G}
2 10
5 10
1 10
2 10
5 10
1 10
1 10
2 10
5 10
2 10
5 10
1 10
{20 G}
HC
5
5
6
5
5
6
5
5
5
5
5
6
1c, 2c, 4c
VDE

Related parts for HC2-HP-DC24V-F

HC2-HP-DC24V-F Summary of contents

Page 1

... Half-wave pulse of sine wave: 6ms Expected life (min. operations) Electrical (at 20 cpm) Voltage Resistive Load (cos = 1) 10A HC1 Current 7A (1 Form HC2 Current 5A (2 Form HC3 Current — (3 Form HC4 Current 3A (4 Form C) 2A Mechanical life (at 180 cpm) MINIATURE RELAY FOR ...

Page 2

... D: Bifurcated contact type 3: 3 Form C (HC4D only. See Page 302 Form C K: Latching relay type (HC2K only. See Page 303.) Notes: 1. When ordering VDE recognized types, add suffix VDE. 2. HC3 (3 Form C) series are not approved by VDE type is not available for LED wiring. ...

Page 3

... General tolerance: 0.2 .008 Schematic (bottom view) HC1-H, HC1-HP (1 Form C) HC2-H, HC2-HP (2 Form LED AC type LED DC type HC2-H (2 Form C) HC3-H (3 Form C) 20 ...

Page 4

... Form C type (HC4D only. See Page 302.) UL/CSA approved type is standard. REFERENCE DATA (HC Amber Relays) 1. Switching capacity range 250V 100V HC4E 10V HC2E HC1E 10mA 10A AC current arrangements of 1 Form C, 2C, and 4C are available for plug-in, PC board and top-mount. Construction The diagram at right shows a cross- section of the plastic sealed relay ...

Page 5

... the power circuit 250 V AC resistive load. Therefore, with HC4D type such a usage is possible that one contact switches 100 A and another contact switches 3 A load. Also Amber sealed types are available as HC4ED relays. SPECIFICATIONS Contacts Contact arrangement Contact material Nominal switching capacity Max ...

Page 6

... HC4 types. Standard sockets and screw terminal sockets of HC4 can be used: HC4-SS-K, HC4-PS-K, HC4-WS-K, and HC4-HSF-K. 27.4 1.079 2. Please note that circuit diagram of HC2K is different from HC4. 3. Avoid operation by capacitor since latching force varies according to input pulse voltage. .004 HC ...

Page 7

... Socket for wrap wiring — (with hold-down clip) Screw terminal socket for front wiring — (with hold-down clip) Screw terminal socket for DIN rail assembly (with hold-down clip) HC2 (2 Form C) HC3 (3 Form C) HC2-SS-K HC3-SS-K HC2-PS-K HC3-PS-K — — HC2-SF-K HC3-HSF-K Exclusively for HC2-H ...

Page 8

... HC2-PS-K .156 .060 4.45 0.25 4.45 .010 .175 4.06 .175 .160 29.4 6.35 1.157 .250 25.2 6.35 .992 .250 1.27 .050 21 ...

Page 9

... HC3-SFD-K Hold-down clip (1) Leaf spring: Applied to HC1-SS-K, HC2-SS-K, HC3-SS-K, HC4-SS-K, HC1-PS-K, HC2-PS-K, HC3-PS-K, HC4-PS-K, HC2-SF-K, HC3-HSF-K, HC4-HSF-K Part No.: HC/HL-LEAF-SPRING-K 4.5 0.1 8.6 0.3 .177 .004 .339 .012 2 0.5 .079 .020 20 0 ...

Page 10

... Quick mounting HC2-PS-K HC3-PS-K 4.1 .161 6.35 .250 6.35 .250 13.35 8-2 dia. 13.35 .526 8-.079 dia. HC3-HSF-K Schematic .374 22.5 .886 30 1.181 .079 Minimum separation in tandem mounting HC2-SFD-K Schematic 1.024 30 1.181 .158 12 14 Minimum separation in tandem mounting HC4-SFD-K Schematic N.C. ...

Page 11

... HC Direct mount for HC-TM relay series HC-HTM Notes 1-HTM, HC2-HTM, HC3-HTM, HC4-HTM types all have dimensions in common except for the number of terminals. 2. For the specifications, please refer to Page 297 mounting, use M3 screw and M3 washer. Mounting track for solder socket Track-mounted solder log sockets ...

Related keywords