HC2-HP-DC24V-F Panasonic Electric Works, HC2-HP-DC24V-F Datasheet - Page 5

no-image

HC2-HP-DC24V-F

Manufacturer Part Number
HC2-HP-DC24V-F
Description
RELAY PWR 7A DPDT 24VDC AMB PCB
Manufacturer
Panasonic Electric Works
Series
HCr
Datasheets

Specifications of HC2-HP-DC24V-F

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
37mA
Coil Voltage
24VDC
Turn On Voltage (max)
19.2 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
7A @ 250VAC
Control On Voltage (max)
19.2 VDC
Control Off Voltage (min)
2.4 VDC
Brand/series
HC Series
Current, Rating
7 A
Function
General Purpose
Power, Rating
1750 VA
Standards
UL, CSA, VDE
Termination
Solder
Voltage, Control
24 VDC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2762
HC
2.-(3) Coil temperature rise (4c AC type)
Measured portion: Inside the coil
Ambient temperature: 30 C
Bifurcated contact types HC4D
Extremely high contact reliability has
been made possible by adoption of gold-
clad bifurcated contacts for both movable
and stationary contacts.
HC4D type can be used from the dry
circuit 100 A at 10 V DC to the power
circuit 3 A at 250 V AC resistive load.
Therefore, with HC4D type such a usage
is possible that one contact switches 100
load. Also Amber sealed types are
available as HC4ED relays.
SPECIFICATIONS
Contacts
Expected life (min. operations)
Electrical (at 20 cpm)
REFERENCE DATA
1. Switching capacity range
Standard type
Contact arrangement
Contact material
Rating (resistive)
A and another contact switches 3 A
100mV
250
100
100
90
80
70
60
50
40
30
20
10
HC4ED
Voltage
0
HC4D
Load
80
100 A
90
Voltage applied to coil, %V
86 F
100
Nominal switching capacity
Max. switching power
Max. switching current
Min. switching capacity
AC current
(cos
110
Resistive
1A
3 A
1 A
120
3A
= 1)
2A
125 V AC
10A
#1
(cos
Inductive
2.-(4) Coil temperature rise (1c DC type)
Measured portion: Inside the coil
Ambient temperature: 30 C
Amber type
1 A
100mV
] 0.4)
250
100
100
90
80
70
60
50
40
30
20
10
0
(HC4ED) 100 µA, 100 mV DC
80
(HC4D) 100 µA, 1 V DC
Gold-clad silver nickel
100 A
4 Form C only
(cos
3 A 250 V AC
90
Resistive
Voltage applied to coil, %V
750 VA
3 A
1 A
86 F
100
3A
= 1)
AC current
110
250 V AC
1A
120
3A
5A
0A
(cos
10A
Inductive
0.8 A
] 0.4)
2.-(5) Coil temperature rise (2c DC type)
Measured portion: Inside the coil
Ambient temperature: 30 C
Characteristics
#1 This value can change due to the switching
Operate time
(Approx.)
Release time
(Approx.)
frequency, environmental conditions, and desired
reliability level, therefore it is recommended to
check this with the actual load.
100
90
80
70
60
50
40
30
20
10
0
Resistive
30 V DC
3 A
80
Voltage applied to coil, %V
90
86 F
100
Max. 20 ms
Max. 20 ms
Expected life
110
2 10
120
5A
5

Related parts for HC2-HP-DC24V-F