AEV19012W Panasonic Electric Works, AEV19012W Datasheet - Page 4

RELAY INDUSTRIAL SPST 300A 12VDC

AEV19012W

Manufacturer Part Number
AEV19012W
Description
RELAY INDUSTRIAL SPST 300A 12VDC
Manufacturer
Panasonic Electric Works
Series
AEVr
Datasheet

Specifications of AEV19012W

Relay Type
Automotive
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
300A
Switching Voltage
400VDC
Coil Type
Standard
Coil Current
3.2A
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
2 VDC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
300A @ 400VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2581

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AEV19012W
Manufacturer:
PANASONIC/松下
Quantity:
20 000
EV (AEV)
REFERENCE DATA
1.-(1) Ambient temperature characteristics
(10 A type)
Sample: EV relay 10 A, 3 pcs.
1.-(4) Ambient temperature characteristics
(120 A type)
Sample: EV relay 120 A, 3 pcs.
3. Switching life curve
100000
10000
1000
100
10
-40
-40
1
1
Ambient
temperature, °C
Ambient
temperature, °C
20 A type,
400 V DC resistive load
-20
-20
Pick-Up
voltage
10 A type,
400 V DC resistive load
10
0
0
Contact current, A
-10
-20
-30
-40
-10
-20
-30
-40
40
30
20
10
40
30
20
10
20
20
Pick-Up
voltage
120 A type,
400 V DC resistive load
80 A type,
400 V DC resistive load
300 A type,
400 V DC resistive load
100
40
40
Drop-out
voltage
Drop-out
voltage
60
60
1000
80
80
X
X
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
1.-(2) Ambient temperature characteristics
(20 A type)
Sample: EV relay 20 A, 3 pcs.
1.-(5) Ambient temperature characteristics
(300 A type)
Sample: EV relay 300 A, 3 pcs.
4. Cut-off life curve
1000
100
10
1
-40
-40
100
Ambient
temperature, °C
Ambient
temperature, °C
80 A type,
400 V DC resistive load
(for Min. 600 A,
300 V DC)
120 A type,
400 V DC resistive load
-20
-20
0
0
-10
-20
-30
-40
-10
-20
-30
-40
40
30
20
10
40
30
20
10
Cut-off current, A
1000
20
20
Drop-out
voltage
300 A type,
400 V DC resistive load
(for Min. 900 A,
300 V DC)
Pick-Up
voltage
40
40
Drop-out
voltage
Pick-Up
voltage
60
60
10000
80
80
1.-(3) Ambient temperature characteristics
(80 A type)
Sample: EV relay 80 A, 3 pcs.
2. Max. value for switching capacity
5. Carrying performance curve (80°C 176°F)
*For 300 A, at 85°C
1000
1000
100
10
10
100
10
10
1
-40
5
4
1
1
20 A type,
400 V DC resistive load
Ambient
temperature, °C
80 A type,
400 V DC resistive load
10 A type
-20
Pick-Up
voltage
10
120 A type,
400 V DC resistive load
10
0
185°F
300 A type,
400 V DC resistive load
10 A type,
400 V DC resistive load
20 A type
80 A type
Carrying current, A
Contact voltage, V
-10
-20
-30
-40
40
30
20
10
20
Drop-out
voltage
100
100
40
300 A type
120 A type
60
1000
1000
80

Related parts for AEV19012W