P2CF-08-E Omron, P2CF-08-E Datasheet - Page 20

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Explanation of Functions
Time Range (timr) (Setting possible using DIP switch.)
Set the range to be timed in the range 0.000 s to 9,999 h. Settings of
type ---- h (9,999 h) and ---- min (9,999 min) cannot, however, be
made with the DIP switch. Use the operation keys if these settings
are required.
Timer Mode (timm) (Setting possible using DIP switch.)
Set either the elapsed time (UP) or remaining time (DOWN) mode.
Output Mode (outm) (Setting possible using DIP switch.)
Set the output mode. The possible settings are A, A-1, A-2, A-3, b, b-
1, d, E, F, and Z. Only output modes A, A-2, E, and F can be set
using the DIP switch. Use the operation keys if a different setting is
required. (For details on output mode operation, refer to Timing
Charts on page 22.)
Output Time (otim)
When using one-shot output, set the output time for one-shot output
(0.01 to 99.99 s). One-shot output can be used only if the selected
output mode is A, A-1, A-2, b, or b-1. If the output time is set to 0.00,
hold is displayed, and the output is held.
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON.
Note: Changing mode to timer/twin timer selection mode (
KP-1
(default setting)
KP-2
KP-3
KP-4
KP-5
Note: Factory-set to OFF
(See note)
Level
OFF
ON
Key protect indicator
Meaning
No
No
No
No
No
Changing mode
(See note.)
MODE
+
1
Yes
Yes
Yes
Yes
No
1 s min.) or function setting mode (
Switching display
during operation
Input Signal Width (iflt) (Setting possible using DIP
switch.)
Set the minimum signal input width (20 ms or 1 ms) for signal, reset,
and gate inputs. The same setting is used for all external inputs (sig-
nal, reset, and gate inputs). If contacts are used for the input signal,
set the input signal width to 20 ms. Processing to eliminate chatter-
ing is performed for this setting.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. The same setting is used for all external
inputs. For details on input connections, refer to Input Connections
on page 9.
Display Color (colr)
Set the color used for the present value.
red
grn
r-g
g-r
Red (fixed)
Green (fixed)
Red
Green
Details
Output OFF
Yes
No
Yes
No
No
Reset key
MODE
3 s min.).
Green
Red
Yes
Yes
No
No
No
H5CX-A/-L
Output ON
Up/down key
20

Related parts for P2CF-08-E