P2CF-08-E Omron, P2CF-08-E Datasheet - Page 50

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Safety Precautions (H5CX-B)
■ Precautions for Safe Use
Changing the Set Value
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the use
of a constant read-in system:
Forecast Value Setting
When the present value ≥ the set value, OUT2 (control output) turns
ON. When the present value ≥ the forecast value (forecast value =
set value − forecast set value) OUT1 (forecast output) turns ON.
Absolute Value Setting
When the present value ≥ set value 2, OUT2 (control output 2) turns
ON. When the present value ≥ set value 1, OUT1 (control output 1)
turns ON.
■ Precautions for Correct Use
Operation with a Set Value of 0
When the set value is 0, the output turns ON the moment the signal
is input. The reset operation turns OFF the output.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
H5CX-B