H3CA-A Omron, H3CA-A Datasheet - Page 2

RELAY TIMER SSR SPDT 24V

H3CA-A

Manufacturer Part Number
H3CA-A
Description
RELAY TIMER SSR SPDT 24V
Manufacturer
Omron
Series
H3CAr
Datasheet

Specifications of H3CA-A

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 9990 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
3A @ 250VAC
Voltage - Supply
24 ~ 240VAC, 12 ~ 240VDC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Timing Adjustment Method
Thumbwheel Switches
Timing Initiate Method
Input Voltage
Timing Range
0.1 s to 9990 Hrs
Supply Voltage
24 V to 240 V
Accuracy
+/- 0.3 %, - 0.05 s
Current Rating (max)
3 A
Display Type
LED Backlight
Operating Temperature Range
- 10 C to + 55 C
Output Current
3A
Supply Voltage Max
240VAC
Time Range Max
9990h
Switch Function
SPDT
Time Range Min
0.1s
No. Of Digits / Alpha
3
Supply Voltage Min
24VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CA-A
H3CAA
Z2359
■ Ratings
Note: 1. Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC.
■ Characteristics
Accuracy of operating
time
Influence of voltage
Influence of
temperature
Setting error
Reset time
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
EMC
Weight
Rated supply voltage
(See note 2.)
Operating voltage range
Power consumption
Control outputs
2. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor.
Item
±0.3% ±0.05 s
±0.5% ±0.05 s max.
H3CA-A/-FA: 0.5 s max.
H3CA-8H/-8: 0.1 s max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and
control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
3 kV
Destruction: 10 to 55 Hz with 0.75-mm double amplitude for 1 h each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 98 m/s
Operating: –10°C to 55°C
Operating: 35% to 85%
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
UL508, CSA C22.2 No. 14, LR, NK
Conforms to EN61010-1.
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted
Disturbance:
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interruption
H3CA-A:
H3CA-FA: approx. 190 g
24 to 240 VAC (50/60 Hz),
12 to 240 VDC (permissible ripple:
20% max.)
90% to 110% of rated supply voltage 85% to 110% of rated supply voltage
AC: approx. 4 VA
DC: approx. 2 W
3 A at 250 VAC, resistive load (cosφ = 1)
approx. 110 g
100,000 operations min. (3 A at 250 VAC, cosφ = 1 at 1,800 operations/h)
See Lift-test Curve for more details.
H3CA-A/H3CA-FA
2
2
EN61326
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61326
EN61000-4-2:
EN61000-4-3:
EN61000-4-6:
EN61000-4-4:
EN61000-4-5:
EN61000-4-11:
100/110/120, 200/220/240 VAC, (50/60 Hz),
24 VDC, 110 VDC (permissible ripple: 20% max.) (See note 1.)
AC: approx. 10 VA/1 W
DC: approx. 1 W
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
10 V (0.15 to 80 MHz) (according to EN61000-6-2)
2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
1 kV line to lines (power and output lines) (level 3);
2 kV line to ground (power and output lines) (level 3)
0.5 cycle, 100% (rated voltage)
H3CA-8
AC: approx. 10 VA/1.5 W
DC: approx. 2 W
H3CA-8H
H3CA
2

Related parts for H3CA-A