H5S-WB2 Omron, H5S-WB2 Datasheet

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Weekly Control with a Large Time Display
Easy Programming with Large Display and Interactive
Functions.
• Easy operation with five keys.
• Up to 24 steps of ON/OFF operations can be set.
• Power supply freely selectable from 100 to 240 VAC.
• Memory protection during power failure for up to 10 years.
• Certified for UL and CSA safety standards.
• The same setting can be used for multiple-day operation and
Ordering Information
Specifications
■ Time Ranges
■ Ratings
Screw terminals
24 hrs x 7 days
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
timer operation.
Daily Time Switch
H5L
Refer to Safety Precautions for All Timers.
Refer to Safety Precautions on page 12
Wiring
Rated time
Provided (approx. 10 years at 25°C)
Backup power supply function for memory
protection
100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Approx. 4 VA at 240 VAC
15 A at 250 VAC, resistive load at 50°C
12 A at 250 VAC, resistive load at 55°C
Minimum applied load: 100 mA at 5 VDC (failure level: P, reference value)
00:00 to 23:59
Time setting range
24 (Each ON or OFF is considered to be one step.) H5L-A
96 mm
No. of program steps
1 min
96 mm
Time division
CSM_H5L_DS_E_2_1
Model
1

Related parts for H5S-WB2

H5S-WB2 Summary of contents

Page 1

Daily Time Switch H5L Weekly Control with a Large Time Display Easy Programming with Large Display and Interactive Functions. • Easy operation with five keys. • steps of ON/OFF operations can be set. • Power supply freely ...

Page 2

Characteristics ±0.01% ±0.05 s max. (see note 1) Accuracy of operating time Setting error Influence of voltage Influence of temperature ±15 s per month (at 25°C) Time accuracy Insulation resistance 100 MΩ min. Dielectric strength 2,000 VAC, 50/60 Hz ...

Page 3

Nomenclature LCD Mode Key Write Key Plus Key Minus Key Cycle Key Manual override switch Key Operation Key Name Mode Key Changes program mode Write Key To write the set data using the Plus and/or Minus Key. Reads out the ...

Page 4

Operation ■ Programming The H5L Weekly Timer has the following six program modes. Use the Mode Key to change the modes. Use the Write Key, Plus Key, Minus Key, and Cycle Key for programming in each mode. Mode Change Sequence ...

Page 5

Note: Refer to "Programming Example". 3. The cycle period (from start time to stop time) does not need multiple of the cycle frequency (ON time plus OFF time). The cycle period can be set within a range ...

Page 6

Deleting Programming 1. Deleting from Normal Operation Programs (ON Time/OFF Time) Call up the output display for the program to be deleted by pressing the Write Key. The minus sign (–) for the output point will flash. Next, change the ...

Page 7

Example ON and OFF Programs Cyclic Programs In this example, the first circuit is programmed to turn ON at 7:40 and OFF at 19:30. This circuit is operated from Monday through Friday and stopped on Saturday and Sunday. The second ...

Page 8

First Circuit Operation Setting To program the operation of the first circuit, "hour", "minute", and "output" must be specified. Press the Mode Key to place the H5L into PROG 1 mode. The display will be as shown on the ...

Page 9

Second Circuit Operation Setting Press the Mode Key to place the H5L into PROG 2 mode. The display appears as shown on the left. In this example, as the second circuit cyclically operated, specify the cycle ...

Page 10

Dimensions Note: All units are in millimeters unless otherwise indicated. H5L Dimensions Panel Cutout Dimensions 59.8 (See note 1) 68.5 (See note 2) Note: 1. When using mounting track PFP-100N or PFP-50N. 2. When using mounting track PFP-100N2. ...

Page 11

Accessories (Order Separately) Front Cover Y92A-96A Mounting Track (Meets DIN EN 50022) PFP-100N/PFP-50N (See note) (See note 2) PFP-100N2 Twelve,-25 × 4.5 elliptic holes (See note 2) (See note) PFP-100N 1 m PFP-50N 50 cm PFP-100N2 1 m Installation ...

Page 12

Safety Precautions Refer to Safety Precautions for All Timers. !CAUTION Tighten terminal screws to the specified torque of approx. 0.8 N·m (maximum torque: 0.98 N·m). Loose screws may occasionally cause fires or malfunction. The Time Switch contains a lithium battery ...

Page 13

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. H5L 13 ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords