H5S-WB2 Omron, H5S-WB2 Datasheet

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Easier, More Convenient Time Switches, with
New 4-circuit Output and Yearly Models in
Addition to 2-circuit Weekly Models
• Independent Day Keys provide easier operation.
• Temporary holiday setting function makes it easy to turn OFF output
• Settings can be made even with the Time Switch turned OFF.
• Test mode enables easy program checking.
• Complies with EMC Directives, UL/CSA, and other safety standards.
• Includes summer time (DST) adjustment.
• Set value can be changed both upward and downward for speedier
• Integrated temperature compensation circuit helps keep accurate
• Includes time counter and total counter functions with alarm indicator.
• Bank function allows program switching by an external input. (See
• New 4-circuit output models with a compact, 72
Note: 1. Available only on yearly models.
Features
Easier and More Convenient to Use
Time Counter/Total Counter Functions (See note.)
This function makes it possible to monitor the total time that a load
has been applied, or the total number of operating cycles. It allows
the Time Switch to be used for managing maintenance.
for holidays and non-operating days.
Yearly models also offer automatic switching to DST.
setting.
time over a wide temperature range. (See note 1.)
(See note 2.)
note 3.)
added to the series.
Digital Time Switch
H5S
Independent Day Keys make setting easy.
Simple Setting
Convenient Functions
2. Available only on 2-circuit models.
3. Available only on weekly models.
With alarm indicator
Shows total lamp ON time
Up/down set value changing
for speedy setting.
Temporary holidays
(non-operating days)
are also easy to set.
Weekly models: Specify the day.
Yearly models: Specify the date.
72-mm DIN size
Time Adjustment Function (See note.)
The time can be set to 00 min 00 s by using an external input. The
times on multiple Time Switches can also be easily synchronized.
Note: Equipped on 2-circuit models.
Master
Digital Time Switch
Slave
Synchronized!
Slave
H5S
1

Related parts for H5S-WB2

H5S-WB2 Summary of contents

Page 1

... Shows total lamp ON time 72-mm DIN size Time Adjustment Function (See note.) The time can be set to 00 min using an external input. The times on multiple Time Switches can also be easily synchronized. Master Note: Equipped on 2-circuit models. Digital Time Switch Synchronized! Slave Slave H5S 1 ...

Page 2

... This ensures precise operation with minimal time lags all year round, regardless of temperature changes. Model Number Structure Model Number Legend Note: This model number legend includes combinations that are not available. Please check the “List of Models” for availability. H5S- @@@@@ - @ Control cycle W: Weekly ...

Page 3

... Weekly 2-circuit Models Yearly 2-circuit Models (H5S-W@2) (H5S-Y@2) Approx. 3 264 VAC 60 Hz Approx. 0 28.8 VDC 2 circuits Supply voltage Models 100 to 240 VAC H5S-WB2 24 VDC H5S-WB2D 100 to 240 VAC H5S-WFB2 24 VDC H5S-WFB2D 100 to 240 VAC H5S-YB2-X 24 VDC H5S-YB2D-X 100 to 240 VAC H5S-YFB2-X 24 VDC ...

Page 4

... EN 60730-2-7 (IEC 61000-4-4 power line 1 kV control line EN 60730-2-7 (IEC 61000-4-5 line to line (power line, output line line to ground (power line, output 0.5 kV line to line (input line line to ground (input line) EN 60730-2-7 (IEC 61000-4-11): 0.5-s cycle, 100% (rated voltage) Yearly 4-circuit Models (H5S-Y@4) ...

Page 5

... For details, refer to About Yearly Programs on page 18. Adds a yearly pulse-output operation to the weekly pulse-output program. For details, refer to About Yearly Programs on page 18. --- Yearly 4-circuit Models (H5S-Y@4) 48 steps/circuit (See note 2.) 12 steps/circuit (See note 3.) Yearly 4-circuit Models (H5S-Y@4) H5S Digital Time Switch 5 ...

Page 6

... The display illumination will turn OFF when there has been no operation for 2 min. The display will light again when any key other than a slide switch is pressed for at least 1 s. • No output will be generated. H5S 6 Digital Time Switch Yearly 2-circuit Models (H5S-Y@2) --- --- --- --- Allows weekly programs to be automatically switched in response to seasons throughout the year ...

Page 7

... Connections Terminal Arrangement H5S-@A@/-@B@ Flush Mounting Models (2-circuit models) Output 2 Input (Rear View Power Output 1 source H5S-@FA@/-@FB@ Surface Mounting Models (2-circuit models) Input Output (Front View Output 1 Power source Note: 1. The Time Switch output uses a no-voltage contact. An external power supply is required for applications in which a load is driven. ...

Page 8

... Output ON/OFF Switches 11. Output Setting Switches 10. Time Adjustment 9. Test/ Key Year 8. Cycle Key Key H5S 8 Digital Time Switch Key Operations No. 1 (2-circuit models) P1: Circuit (output) 1 Setting mode P2: Circuit (output) 2 Setting mode RUN: RUN mode (4-circuit models) 1. Mode PRGM: Setting mode (allows use of the Select Program Key ...

Page 9

... Displays the current day or the day set for an 17 operation. 4. Main display Displays the number of the circuit (output) for 18 5. Pulse width unit which output is ON. indicator 7. Display of number of remaining steps 8. Set circuit number indicator 9. Sub-display 2. AM/PM indicator 10. Timing chart display 15. Year indicator Digital Time Switch Function H5S 9 ...

Page 10

... Use a tool such as long nose pliers to prepare the openings for pulling wires. Note: 1. The terminal screws are M3.5. 2. This illustration shows a 2-circuit model. The 4-circuit model has the same dimensions. H5S 10 Digital Time Switch 9.5 (53.2) Two terminal covers (included) ...

Page 11

... The numbers in parentheses ( ) are dimensions for the PFP-50N End Plate PFP pan-head screw 50 11 spring washer DIN Track Mounting Base Y92F-90 Note: The DIN Track Mounting Base can be used only with the surface mounting models (H5S-@FA@/-@FB@). PFP-100N2 7.3 0.15 4 0.3 0. Spacer 10 6 ...

Page 12

... Install the Time Switch well away from any sources of excessive static electricity, such as pipes transporting molding materials, powders, or liquids. 9. Maintain voltage fluctuations in the power supply within the specified range. H5S 12 Digital Time Switch 10.Internal elements may be destroyed if a voltage outside the rated voltage is applied. ...

Page 13

... Voltage (SELV) circuit is desired, supplementary insulation must be provided. • Use crimp type cable lug terminals with insulating sleeves for wiring. • Be sure to mount a surface-mounting model (H5S-@FB enclosure. Basic Use Prior to Using Before setting the parameters necessary for each operation, the operation of each circuit (output) must be determined. Begin by setting initial setting mode as required ...

Page 14

... If is pressed again before TIME ADJ pressing , the setting is WRITE cancelled. (The setting is not revised.) H5S 14 Digital Time Switch Time Adjustment (Yearly Models) Yearly, 2 Circuits Example: Set the current time to 17:28 on August 15, 2006. 1. Set the Mode Shaded portion indicates Switch to RUN ...

Page 15

... Friday SUN MON TUE WED THU FRI SAT h and enter the settings. WRITE WRITE repeatedly until “--:--“ h and m Keys rapidly advances the value. decrements the value of the key that was last H5S Digital Time Switch SAT Number of remaining steps 15 ...

Page 16

... To add another program, press WRITE is displayed Holding down the and m Keys rapidly advances the value. Pressing decrements the value of the key that was last pressed. H5S 16 Digital Time Switch Pulse-output Operation Weekly, 2 Circuits Example: ON for 30 seconds at 8:25 am from Monday through FRI SAT SUN 8 22 ...

Page 17

... SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT repeatedly until “--:--“ WRITE in program setting mode. H5S Digital Time Switch 17 ...

Page 18

... Program A March 25, 2006 (Start date) April 8, 2006 (End date) 18:00 (ON time) SUN MON TUE WED THU FRI SAT 12:00 (OFF time) Note: Do not enter a weekly program. ProgramA ProgramB Output performance of H5S Yearly, 4 Circuits 3/22(THU) 3/23(FRI) 3/24(SAT) 3/25(SUN) 3/26(MON 22: ...

Page 19

... YEAR for more. (The and PLS . ··· ··· enter the settings. WRITE repeatedly until “--:--“ is displayed. decrements the value of the key that was last pressed. in yearly program setting mode. H5S Digital Time Switch Number of remaining steps 19 ...

Page 20

... The setting is automatically cleared after the set holiday has passed. • All ON operations are cancelled on the holiday. • The set holidays are valid for all the output circuits. H5S 20 Digital Time Switch Setting Temporary Holidays (Yearly) Yearly, 2 Circuits Temporary* holidays (non-operating days) can be set simply by specifying dates ...

Page 21

... SUN MON TUE WED THU FRI SAT ) at the position SUN MON TUE WED THU FRI SAT to enter the setting. Yearly, 2 Circuits Yearly, 4 Circuits +1h is pressed for more in RUN mode, the current SUN MON TUE WED THU FRI SAT H5S Digital Time Switch 21 ...

Page 22

... Yearly, 4 Circuits Current time Current time Current month and day Next operation (Factory setting) H5S 22 Digital Time Switch Override and Automatic Return Operation Weekly, 2 Circuits Helps to cope with sudden schedule changes without having to revise the existing program. This function allows ON/OFF states that were forcibly set using the Output ON/OFF Switch to be maintained until the next ON/OFF time ...

Page 23

... Using Advanced Functions About Advanced Functions Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following pages. Refer to the Instruction Manual enclosed with the H5S for details. Initial Setting Mode Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits ...

Page 24

... Press h or display to sync. 2. Press WRITE Manual Operation on Recovery from Power Failure (F2) Weekly, 2 Circuits Yearly, 2 Circuits After power is restored to the H5S possible to set the Time Switch to stop turning ON output until external input is applied. Power supply External input Output ON OFF Flashing ON ...

Page 25

... Yearly, 4 Circuits indicate the default. 1. Press select one of the parameters. 2. Press to enter the setting. WRITE Yearly, 4 Circuits indicate the default Press or to select one of the parameters. 2. Press WRITE to enter the setting. H5S Digital Time Switch 25 ...

Page 26

... The following indications will be displayed when an error is generated. Indication Description e1 CPU error OFF e2 Memory error OFF H5S 26 Digital Time Switch Summer time end date and time At 2:00 on the last Sunday in October At 3:00 on the last Sunday in October At 3:00 on the last Sunday in March ...

Page 27

... H5S Digital Time Switch 27 ...

Page 28

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 29

Cat. No. L014-E1-07 Specifications subject to change without notice 12/04 Printed in USA ...