H5S-WB2 Omron, H5S-WB2 Datasheet - Page 19

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Yearly Timer Operation
Yearly, 2 Circuits
Example: ON at 18:00 and OFF at 22:15 on March 25 every year.
1. Set the Mode Switch to P1 or P2.
2. Press
3. Specify the start date using
4. Press
5. Press
6. Press
7. Press
*1 If one or more programs have already been set, the display starts showing the
*2 Holding down the date- or time-setting keys rapidly advances the value.
Note:
Set the program in the following order.
Yearly programs are added to weekly programs.
All the start/end dates and ON/OFF times must be set. the maximum
number of yearly timer operations that can be set is four for each output
circuit.
If multiple settings are required, repeat steps 3 through 7.
All of the yearly programs for the selected circuit (output) can be checked by
pressing
The set data will be cleared if the Output Setting Switch is moved between
the TIMER and PULSE positions after the data has been set.
set programs.
To add another program, press
Pressing
Time Switch enters yearly program
setting mode. *1)
and
The year can be set from the current
year to the next two years as shown
in the example. If the year is set to
“--”, the operation performs every
year.
<Example>
If the current year is 2006, the
displayed year changes as follows.
--
Specify the end date using
and
If the starting year has been set to
“--”, the ending year cannot be set.
Set the ON time with
Set the OFF time with
Day
period
Time
period
For 4-circuit models, refer to
page 18.
RUN
D
D
06
P1
P2
WRITE
WRITE
WRITE
WRITE
WRITE
YEAR
. *2
. *2
March 25, 2006 (Start date)
March 25, 2006 (End date)
18:00 (ON time)
22:15 (OFF time)
decrements the value of the key that was last pressed.
07
.
.
.
for 1 s or more. (The
in yearly program setting mode.
to enter the settings.
PULSE
TIMER
Yearly, 4 Circuits
08
h
h
--
WRITE
and
and
Y
Y
06
m
,
,
m
m
repeatedly until “--:--“ is displayed.
. *2
m
. *2
Shaded portion indicates
blinking of the indicator.
SUN MON TUE WED THU FRI SAT
remaining steps
Number of
Yearly Pulse-output Operation
Yearly, 2 Circuits
Example: To produce output for 2 minutes at 18:00 from March 25 to
1. Set the Mode Switch to P1 or P2.
2. Press
3. Specify the start date using
4. Press
5. Press
6. Press
7. Press
*1 If one or more programs have already been set, the display starts showing the
*2 Holding down the date- or time-setting keys rapidly advances the value.
Note:
Yearly programs are added to weekly programs.
All the start/end dates, ON time, and pulse width must be set. The maximum
number of yearly pulse output operations that can be set is four for each
output circuit.
If multiple settings are required, repeat steps 3 through 7.
All of the yearly programs for the selected circuit (output) can be checked by
pressing
The set data will be cleared if the Output Setting Switch is moved between
the TIMER and PULSE positions after the data has been set.
set programs.
To add another program, press
Pressing
Set the program in the following order.
Time Switch enters yearly program
setting mode. *1)
and
The year can be set from the current
year to the next two years as shown in
the example. If the year is set to “--” ,
the operation performs every year.
<Example>
If the current year is 2006, the
displayed year changes as follows.
--
Specify the end date using
and
If the starting year has been set to
“--”, the ending year cannot be set.
Set the ON time with
Set the pulse width with
The displayed pulse width changes
by pressing this key in the following
order.
1 s
59 m
Day
period
For 4-circuit models, refer to
page 18.
Time
period
RUN
D
D
06
P1
P2
2 s
WRITE
WRITE
WRITE
WRITE
WRITE
April 9.
YEAR
. *2
. *2
60 m
decrements the value of the key that was last pressed.
March 25, 2006 (Start date)
April 9, 2006 (End date)
18:00 (ON time)
2 minutes (Pulse width)
07
··· 59 s
.
.
.
for 1 s or more. (The
to enter the settings.
in yearly program setting mode.
PULSE
TIMER
Yearly, 4 Circuits
1 s
08
Digital Time Switch
h
1 m
--
and
WRITE
PLS
Y
Y
06
···
.
,
,
m
m
m
repeatedly until “--:--“ is displayed.
. *2
Shaded portion indicates
blinking of the indicator.
SUN MON TUE WED THU FRI SAT
H5S
remaining steps
Number of
19