PM5S-A-24-240V Panasonic Electric Works, PM5S-A-24-240V Datasheet - Page 7

TIMER RELAY ANALOG 24-240V

PM5S-A-24-240V

Manufacturer Part Number
PM5S-A-24-240V
Description
TIMER RELAY ANALOG 24-240V
Manufacturer
Panasonic Electric Works
Series
PM5Sr
Type
Timerr
Datasheets

Specifications of PM5S-A-24-240V

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 500 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 240VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2831

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5S-A-24-240V
Manufacturer:
Panasonic Electric Works
Quantity:
135
PM5S-A/S/M
Input connections
The inputs of the PM5S-A/M are voltage (voltage imposition or
open) inputs.
No-contact input
(Connection to PNP output sensor.)
Voltage Input Signal Levels
Cautions for use
Cautions
1) Prevent using the timer in such places
where flammable or corrosive gas is
generated, a lot of dust exisits, oil is
splashed or considerable shock and
vibration occur.
Power supplies
The PM5S Series is provided with a
transformerless power supply system.
An electric shock may be received if the
input terminal or the output type selector
switch is touched while power is being
supplied.
Use the bar terminal for wiring the
PM5S. Using a stranded-wire terminal
may cause a short-circuit due to a stray
wire entering into the Timer.
78
No-contact
input
Contact
input
Operates with transistor ON
24 V DC
Sensor
1. Transistor ON
Residual voltage: 1 V max.
(Voltage between terminals B
“H-level” voltage (20.4 V DC min.).)
2. Transistor OFF
Leakage current: 0.01 mA max.
(Voltage between terminals B
“L-level” voltage (2.5 V DC max.).)
Use contacts that can adequately switch 0.1 mA at each voltage to
be imposed. (When the contacts are ON or OFF, voltage between
terminals B
When contacts are ON: 20.4 to 264 V AC/DC
When contacts are OFF: 0 to 2.5 V AC/DC
Start
B
1
A
2
1
and A
A
1
Timer
2
must be within the following ranges:
1
1
and A
and A
Contact input
Operates with relay ON
2
2
must be more than the rated
must be less than the rated
2) Since the body cover is consisted of
polycarbonate resin, prevent from con-
tact with organic solvents such as methyl
alcohol, benzine and thinner, or strong
alkali materials such as ammonia and
caustic soda.
For the power supply of the input device,
use a single-phase or double-phase
insulated power transformer. The sec-
ond-phase side must not be grounded.
Start
B
1
A
Circuit
2
input
Start
A
B1
1
Timer
PM5S
A1
A2
Isolation tranformer is required.
Mounting and dismounting
The PM5S should be mounted as horizontally as possible.
When mounting the PM5S on a socket mounting track, hook
portion (A) of the Timer to an edge of the track first, and then
depress the Timer in the direction of (B).
When dismounting the PM5S pull out portion (C) with a flat-
blade screwdriver and remove the Timer from the mounting
track.
Power supply
• Input and Power supply circuit
(PM5S-A/M)
• Since input circuit and power supply
circuit is independent, it is possible to
switch ON and OFF for input circuit
regardless power ON and OFF.
Note that the contact of input circuit is
given same voltage as power voltage.
Power supply
AC/DC
(C)
Rail stopper
Input circuit
(A)
B1
(B)
A2
Power supply
circuit
A1

Related parts for PM5S-A-24-240V