PDH10-37 Panduit Corp, PDH10-37 Datasheet - Page 26

no-image

PDH10-37

Manufacturer Part Number
PDH10-37
Description
HOSE AIR SUPPLY
Manufacturer
Panduit Corp
Type
Accessory, Hoser
Datasheet

Specifications of PDH10-37

Features
-
For Use With/related Products
-
STATUS 3 - Reset EEPROM
STATUS 4 - Reset dispenser RAM
STATUS 5 - Reset tool RAM
MAINTENANCE
DAILY PREVENTIVE MAINTENANCE
The following maintenance of the PAT1M/PAT1.5M System must be performed daily (as needed) to ensure optimum
performance and trouble-free operation of the system.
EXTENDED MAINTENANCE
The following maintenance of the PAT1M/PAT1.5M System must be completed within the recommended intervals to
ensure trouble-free operation and longevity of the system. Certain extended maintenance procedures must be
performed by your maintenance department. Please notify your maintenance department when these specific
maintenance intervals are reached.
No more than 180 cycles
No more than 2500 cycles (= ½ cable tie reel)
PAT1M/PAT1.5M: PA22222A01_03
CAUTION: SAFETY GLASSES WITH SIDE SHIELDS MUST BE WORN AT ALL TIMES DURING
THE MAINTENANCE OR ADJUSTMENT OF THE PAT1M / PAT1.5M TOOLS.
CAUTION: ALWAYS DISCONNECT AIR SUPPLY FROM TOOL BEFORE DISASSEMBLY.
CAUTION: ELECTROSTATIC SENSITIVE DEVICE. DO NOT OPEN OR HANDLE EXCEPT AT A
STATIC FREE WORK STATION.
Reset EEPROM
Reset dispenser RAM
Reset tool RAM
INTERVAL
PAT1M / PAT1.5M OPERATION MANUAL
Empty tool tip collector before full.
(Refer to the Tip Collector section on Page 14.)
Empty dispenser carrier strip scrap bin.
(Refer to the Reloading Procedure section on Page 9.)
Page: 24 of 36
MAINTENANCE PROCEDURE