CST206-1A Triad Magnetics, CST206-1A Datasheet

TRANSF 14MH CRNT SENSE

CST206-1A

Manufacturer Part Number
CST206-1A
Description
TRANSF 14MH CRNT SENSE
Manufacturer
Triad Magnetics
Series
CST206r
Type
Current Senser
Datasheets

Specifications of CST206-1A

Transformer Type
Frequency 20-200kHz
Turns Ratio - Primary:secondary
1 : 100
Inductance
14mH
Current Rating
110A
Dc Resistance (dcr)
580 mOhm Max
E.t.
2000V µS
Mounting Type
PCB
Frequency Range
20 KHz to 200 KHz
Termination Style
Radial
Dimensions
27.3 mm L x 10.16 mm W x 31.11 mm H
Product
Current Sense Transformers
Brand/series
CST Series
Configuration
Encapsulated
Current, Primary
110 A
Frequency
20-200 kHz
Number Of Outlets
1
Number Of Turns
100
Phase
1
Resistance, Dc
0.58 Ohms
Standards
UL
Temperature, Operating
+40 °C
Termination
Thru-Hole
Input Current
110A
Turns Ratio
100
Dc Resistance Max
0.58ohm
Rohs Compliant
Yes
Transformer Mounting
Through Hole
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10508
237-1096

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CST206-1A
Manufacturer:
Triad Magnetics
Quantity:
1 831
CST206-1A
Description:
Designed for switching power supply applications, Triad current sense
transformers are used to detect the current passing through a conductor.
These transformers are very reliable and operate over the frequency range of
20 kHz-200 kHz.
Electrical Specifications (@25C)
Safety:
These current sense transformers are constructed of UL rated 130°C materials.
Dimensions:
.360
Units: In inches
Technical Notes:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
Min
RoHS Compliance:
A
REF 20kHz
ET VµSEC
1. START OF TEST CONDUCTOR TO HAVE
2. DECAL ARROW ON CASE TO INDICATE
1. Derate ET product by 32% for 50 kHz, 52% for 100Hz and 50% for
2. Rated primary current renders approximately 40°C temp. rise.
3. Maximum recommended terminating resistance of 1 ohm per turn.
4. Primary is inserted through hole in casting.
THE SAME POLARITY AS PIN 1
POLARITY
2000
1.225
Max
unidirectional operation.
B
.700
Ref
C
Count
Turns
100
.127
As of manufacturing date February 2005, all standard
Ref
D
.500
Ref
E
Ind. mH
Max
.400
Min.
14.0
F
1
1.075
Max
G
DCR Max. Ω
PIN 1
ARROW
Dia. Pins
ST
POLARITY DETAIL TOP VIEW
.580
.045
H
Current Sense Transformers
110.0 RMS
Pri. Amps
TEST CONDUCTOR
A
D
F
G
C
C L
H
B

Related parts for CST206-1A

CST206-1A Summary of contents

Page 1

... CST206-1A Description: Designed for switching power supply applications, Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate over the frequency range of 20 kHz-200 kHz. Electrical Specifications (@25C) ET VµSEC Turns REF 20kHz Count Ind ...

Page 2

... These transformers are very reliable and operate effectively over the frequency range of 20 kHz-200 kHz. They are constructed of UL rated 130ºC materials. Both models are available with a center tap option. Section/ Type ET VμSEC Tuurns Figure No. REF 20 kHz Count A CST206-1A 2000 100 B CST206-1T 2000 100 CT A CST206-2A 4000 200 B ...

Page 3

... Turns ratio: Primary to sense 1:500 2. Suggested burden resistor: 60 ohms. 3. Typical ouput: 110 mV /Amp Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate effectively between 50-60 Hz. They are constructed of UL rated 130ºC materials ...

Related keywords