ZX-EDA11 2M Omron, ZX-EDA11 2M Datasheet - Page 10

AMP UNIT 12-24VDC PWR SPLY NPN

ZX-EDA11 2M

Manufacturer Part Number
ZX-EDA11 2M
Description
AMP UNIT 12-24VDC PWR SPLY NPN
Manufacturer
Omron
Datasheets

Specifications of ZX-EDA11 2M

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZX-EDA112M
ZXEDA112M
Connectors
Do not connect or disconnect connectors while the power is ON.
Be sure hold to connectors by the cover when connecting or discon-
necting.
Mounting
Handling
When mounting the Sensor Head, do not apply excessive shock by,
for example, using a hammer. Doing so may result in damage or a re-
duction in the level of water-proofing. Also, there are screw-shaped
models that require a toothed washer to allow for a tolerance in the
tightening torque for the nut.
When using a heat-resistant model like the ZX-EM02HT, develop de-
signs that account for thermal expansion due to rising sensing object
temperature so the sensing object will never touch the sensing sur-
face. Also note that any sudden rise in temperature will shorten the
service life of the product.
Tightening Torque
Do not apply excessive torque when tightening the nut. Use a toothed
washer if necessary.
Note:
Mounting Cylindrical Models:
Tighten set screws with a tightening torque of 0.2 N·m max.
Installation Location
Do not install the product in the following locations.
• Locations subject to temperatures outside the specified range
• Locations subject to condensation due to sudden temperature
• Locations subject to humidity levels outside range 35% to 85%
• Locations subject to corrosive or flammable gases
• Locations subject to dust, salts, or metallic powder.
• Locations directly subject to vibrations and shocks
• Locations subject to direct sunlight
• Locations subject to splashes of water, oil, or chemicals
• Locations subject to strong electromagnetic or electrical fields
Maintenance and Inspection
• Be sure to turn OFF the power supply before adjusting or removing
• Cleaning:
10
ZX-EM02T
ZX-EM07MT
ZX-EM02HT
ZX-EDR5T
ZX-ED01T
ZX-ED02T
changes
the Sensor Head.
Do not use thinners, benzine, acetone, or kerosene for cleaning.
The above figure applies for use with a toothed washer.
Model
Set screw hole
Model
ZX-E Series
15 N·m
59 N·m
9 to 18 mm
11 to 22 mm
A
Tightening torque
A
Smart Sensors (Inductive Displacement Type)
Y92E-F5R4 (for 5.4-dia.
screws), sold separately
Mounting Bracket