ZX-EDA11 2M Omron, ZX-EDA11 2M Datasheet - Page 3

AMP UNIT 12-24VDC PWR SPLY NPN

ZX-EDA11 2M

Manufacturer Part Number
ZX-EDA11 2M
Description
AMP UNIT 12-24VDC PWR SPLY NPN
Manufacturer
Omron
Datasheets

Specifications of ZX-EDA11 2M

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZX-EDA112M
ZXEDA112M
■ Amplifier Units
Measurement period *1
Possible average count settings
Linear output *2
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
Zero reset input, timing input, reset
input, judgement output hold input
Function
Indications
Voltage influence (including Sensor) 0.5% F.S. of linear output value at ±20% of power supply voltage
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Connection method
Weight (packed state)
Materials
Accessories
*1:Resolution: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-EDA Amplifier Unit. The above values indicate
*2: Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The
*3: Temperature characteristic: The temperature characteristic is measured with OMRON's standard reference object at 1/2 of the measure-
*4: The ambient temperature given is only for the sensor head. It is -10 to 60°C for the preamp.
*5: The value given is for an ambient temperature of 25°C.
*6: Do not use in moist environments because the case is not waterproof.
*1:The response time for the first linear output or judgment output is calculated as follows (with fixed sensitivity): Measurement period × (Aver-
*2: The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
*3: Setting is possible via the monitor focus function.
*4: A Calculating Unit (ZX-CAL2) is required.
the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with OMRON's standard reference object at 1/2 of the measurement range with the ZX-EDA set for the maxi-
mum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution
may be adversely affected under strong electromagnetic fields.
linearity and measurement values vary with the object being measured.
ment range.
age count setting + 1). The response time for the second and later outputs is the measurement period specified in the table.
Model
150 μs
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω
Voltage output: ±4 V (± 5 V, 1 to 5 V *3), Output impedance: 100 Ω
NPN open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 1.2 V max.
ON:
OFF: Open (leakage current: 0.1 mA max.)
- Measurement value display
- Linearity adjustment (materials selection)
- Display reverse
- Number of display digit changes
- Bottom hold, peak-to-peak hold
- Average hold
- Initial reset
- OFF-delay timer
- Non-measurement setting
- Automatic teaching
- Reset input
- Linear output correction
- K-(A+B) calculation *4
- Sensor disconnection detection
- Key lock
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red),
7-segment sub-digital display (yellow), power ON (green), zero reset (green), enable (green)
12 to 24 VDC ±10%, Ripple (p-p): 10% max.
140 mA max. with power supply voltage of 24 VDC (with Sensor connected)
Operating and storage: 0 to 50°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 DC)
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions
300 m/s
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Instruction Manual
Short-circuited with 0-V terminal or 1.5 V or
less
2
, 3 times each in 6 directions (up, down, left, right, forward, backward)
ZX-E Series
ZX-EDA11
Smart Sensors (Inductive Displacement Type)
- Set value/output value/resolution display
- Display OFF mode
- Sample hold
- Self-peak hold
- Delay hold
- Linearity initialization
- One-shot timer
- Direct threshold value setting - Position teaching
- Hysteresis width setting
- Judgement output hold input - Monitor focus
- (A-B) calculations *4
- Mutual interference prevention *4
- Zero reset memory
PNP open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 2 V max.
ON:
OFF: Open (leakage current: 0.1 mA max.)
Supply voltage short-circuited or supply volt-
age within 1.5 V
- Scaling
- ECO mode
- Peak hold
- Self-bottom hold
- Zero reset
- ON-delay timer
- Previous value comparison
- Timing inputs
- (A+B) calculations *4
- Zero reset indicator
ZX-EDA41
3

Related parts for ZX-EDA11 2M