B45396R0108K509V10 Kemet, B45396R0108K509V10 Datasheet - Page 10

CAP TANT 1000UF 4V 10% LOESR SMD

B45396R0108K509V10

Manufacturer Part Number
B45396R0108K509V10
Description
CAP TANT 1000UF 4V 10% LOESR SMD
Manufacturer
Kemet
Series
B45396Rr
Type
Moldedr
Datasheet

Specifications of B45396R0108K509V10

Capacitance
1000µF
Voltage - Rated
4V
Tolerance
±10%
Esr (equivalent Series Resistance)
30.0 mOhm
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
2917 (7343 Metric)
Size / Dimension
0.287" L x 0.169" W (7.30mm x 4.30mm)
Height
0.161" (4.10mm)
Manufacturer Size Code
E
Features
General Purpose
Voltage Rating
4 Volts
Esr
30 mOhms
Operating Temperature Range
- 55 C to + 125 C
Dimensions
4.3 mm W x 7.3 mm L x 4.1 mm H
Dissipation Factor Df
6
Leakage Current
40 uA
Product
Tantalum Solid Low ESR Standard Grade
Termination Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Spacing
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
495-1607-2
B45396R0108K509
Cautions and warnings
When using tantalum capacitors with a manganese dioxide coating, the following cautions and
warnings should be taken into account:
Polarity
Because tantalum capacitors are polar capacitors, it is important to observe their polarity
markings (positive pole on the anode, negative pole on the cathode). Any incorrect polarity
resulting from the sum of the AC and DC voltage components must be smaller than or equal to
the permitted polarity reversal voltage. To avoid reducing their reliability, this voltage may only
occur for a short time, at most five times for a duration of one minute per hour.
Voltage
The maximum continuous voltage depends on the ambient temperature. Within the temperature
range of
+ 85 and + 125 C the maximum continuous voltage must be reduced linearly from the full rated
voltage to 2/3 of it (derating). At 150 C (only B4519*P series) the voltage must be reduced to 1/2
and at 175 C (only B4519*T series) to 1/3 of the rated voltage. Operation below the maximum
continuous voltage has a positive effect on the capacitor’s failure rate. The maximum continuous
voltage must not be exceeded.
All unfavourable operating conditions (such as possible line overvoltages, unfavourable
tolerances of the transformation ratio of the line transformer in the equipment, repeated
overvoltages when the equipment is switched on, high ambient temperatures) must be taken into
account when determining the operating voltage.
The surge voltage is the maximum voltage (peak value) that may be applied to the capacitor for
short periods, at most five times for a total duration of up to 1 minute per hour. The surge voltage
must not be applied for periodic charging and discharging in the course of normal operation and
cannot be part of the operating voltage. The permissible surge voltage for all capacitors in this
data book is 1.3 x the rated voltage. The occurrence of voltage impulses (transient voltages) that
exceed the surge voltage may lead to irreparable damage.
Capacitance
The actual capacitance of a capacitor can deviate from the rated capacitance by as much as the
full magnitude of the tolerance at delivery. The capacitance varies with the temperature (at
+125 C +12% up to +20%) and decreases with increasing frequency.
Please read Important notes and
Cautions and warnings at the end of this document.
Tantalum chip capacitors
Multiple Anode, Ultra-low ESR
55 to +85 C, the rated voltage is equal to the maximum continuous voltage. Between
Page 10 of 12