C8051F301-GS Silicon Laboratories Inc, C8051F301-GS Datasheet - Page 155

IC 8051 MCU 8K FLASH 14-SOIC

C8051F301-GS

Manufacturer Part Number
C8051F301-GS
Description
IC 8051 MCU 8K FLASH 14-SOIC
Manufacturer
Silicon Laboratories Inc
Series
C8051F30xr
Datasheets

Specifications of C8051F301-GS

Program Memory Type
FLASH
Program Memory Size
8KB (8K x 8)
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051F3x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
I2C/SMBus/UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
8
Number Of Timers
3
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F300DK
Minimum Operating Temperature
- 40 C
Package
14SOIC
Device Core
8051
Family Name
C8051F30x
Maximum Speed
25 MHz
Operating Supply Voltage
3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
770-1006 - ISP 4PORT FOR SILABS C8051F MCU336-1444 - ADAPTER PROGRAM TOOLSTICK F300336-1319 - REFERENCE DESIGN STEPPER MOTOR
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1536-5
16. Programmable Counter Array
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU
intervention than the standard 8051 counter/timers. The PCA consists of a dedicated 16-bit counter/timer
and three 16-bit capture/compare modules. Each capture/compare module has its own associated I/O line
(CEXn) which is routed through the Crossbar to Port I/O when enabled (See
Crossbar Decoder” on page 104
a programmable timebase that can select between six sources: system clock, system clock divided by four,
system clock divided by twelve, the external oscillator clock source divided by 8, Timer 0 overflow, or an
external clock signal on the ECI input pin. Each capture/compare module may be configured to operate
independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Output, Fre-
quency Output, 8-Bit PWM, or 16-Bit PWM (each mode is described in
Modules” on page
allowing the PCA to be clocked by a precision external oscillator while the internal oscillator drives the sys-
tem clock. The PCA is configured and controlled through the system controller's Special Function Regis-
ters. The basic PCA block diagram is shown in Figure 16.1.
Important Note: The PCA Module 2 may be used as a watchdog timer (WDT), and is enabled in this mode
following a system reset. Access to certain PCA registers is restricted while WDT mode is enabled. See
Section 16.3
for details.
157). The external oscillator clock option is ideal for real-time clock (RTC) functionality,
SYSCLK/12
SYSCLK/4
Timer 0 Overflow
SYSCLK
External Clock/8
ECI
Capture/Compare
Figure 16.1. PCA Block Diagram
Module 0
for details on configuring the Crossbar). The counter/timer is driven by
CLOCK
MUX
PCA
Digital Crossbar
Port I/O
Rev. 2.9
Capture/Compare
16-Bit Counter/Timer
Module 1
C8051F300/1/2/3/4/5
Capture/Compare
Module 2 / WDT
Section “16.2. Capture/Compare
Section “12.1. Priority