ATTINY84V-10SSUR Atmel, ATTINY84V-10SSUR Datasheet - Page 26

no-image

ATTINY84V-10SSUR

Manufacturer Part Number
ATTINY84V-10SSUR
Description
MCU AVR 8KB FLASH 10MHZ 14SOIC
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY84V-10SSUR

Core Processor
AVR
Core Size
8-Bit
Speed
10MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
12
Program Memory Size
8KB (4K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6.2.1
6.2.2
26
ATtiny24/44/84
External Clock
Calibrated Internal 8 MHz Oscillator
To drive the device from an external clock source, CLKI should be driven as shown in
on page
“0000”.
Figure 6-2.
When this clock source is selected, start-up times are determined by the SUT Fuses as shown in
Table
Table 6-3.
When applying an external clock, it is required to avoid sudden changes in the applied clock fre-
quency to ensure stable operation of the MCU. A variation in frequency of more than 2% from
one clock cycle to the next can lead to unpredictable behavior. It is required to ensure that the
MCU is kept in Reset during such changes in the clock frequency.
Note that the System Clock Prescaler can be used to implement run-time changes of the internal
clock frequency while still ensuring stable operation. See
for details.
By default, the Internal Oscillator provides an approximate 8 MHz clock. Though voltage and
temperature dependent, this clock can be very accurately calibrated by the user. See
on page 176
with the CKDIV8 Fuse programmed. See
This clock may be selected as the system clock by programming the CKSEL Fuses as shown in
Table
the pre-programmed calibration value into the OSCCAL Register and thereby automatically cal-
SUT1:0
00
01
10
11
6-3.
6-4. If selected, it will operate with no external components. During reset, hardware loads
26. To run the device on an external clock, the CKSEL Fuses must be programmed to
and
External Clock Drive Configuration
Start-up Times for the External Clock Selection
EXTERNAL
“Internal Oscillator Speed” on page 205
from Power-down
SIGNAL
Start-up Time
CLOCK
6 CK
6 CK
6 CK
“System Clock Prescaler” on page 30
Additional Delay
Reserved
14CK + 64 ms
14CK + 4 ms
from Reset
14CK
CLKI
GND
for more details. The device is shipped
“System Clock Prescaler” on page 30
BOD enabled
Fast rising power
Slowly rising power
Recommended
for more details.
Usage
8006K–AVR–10/10
Table 20-2
Figure 6-2

Related parts for ATTINY84V-10SSUR