AT89LS53-12JI Atmel, AT89LS53-12JI Datasheet - Page 13

IC 8051 MCU FLASH 12K 44PLCC

AT89LS53-12JI

Manufacturer Part Number
AT89LS53-12JI
Description
IC 8051 MCU FLASH 12K 44PLCC
Manufacturer
Atmel
Series
89LSr
Datasheet

Specifications of AT89LS53-12JI

Core Processor
8051
Core Size
8-Bit
Speed
12MHz
Connectivity
SPI, UART/USART
Peripherals
POR, WDT
Number Of I /o
32
Program Memory Size
12KB (12K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
44-PLCC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Data Converters
-
Other names
AT89LS5312JI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89LS53-12JI
Manufacturer:
ATMEL
Quantity:
1 831
Part Number:
AT89LS53-12JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LS53-12JI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Baud Rate Generator
Timer 2 is selected as the baud rate generator by setting
TCLK and/or RCLK in T2CON (Table 2). Note that the baud
rates for transmit and receive can be different if Timer 2 is
used for the receiver or transmitter and Timer 1 is used for
the other function. Setting RCLK and/or TCLK puts Timer 2
into its baud rate generator mode, as shown in Figure 4.
The baud rate generator mode is similar to the auto-reload
mode, in that a rollover in TH2 causes the Timer 2 registers
to be reloaded with the 16 bit value in registers RCAP2H
and RCAP2L, which are preset by software.
The baud rates in Modes 1 and 3 are determined by Timer
2’s overflow rate according to the following equation.
The Timer can be configured for either timer or counter
operation. In most applications, it is configured for timer
operation (CP/T2 = 0). The timer operation is different for
Timer 2 when it is used as a baud rate generator. Normally,
as a timer, it increments every machine cycle (at 1/12 the
oscillator frequency). As a baud rate generator, however, it
increments every state time (at 1/2 the oscillator fre-
quency). The baud rate formula is given below.
Figure 5. Timer 2 in Clock-Out Mode
0851C–MICRO–3/06
Modes 1 and 3 Baud Rates
=
Timer 2 Overflow Rate
----------------------------------------------------------- -
16
where (RCAP2H, RCAP2L) is the content of RCAP2H and
RCAP2L taken as a 16 bit unsigned integer.
Timer 2 as a baud rate generator is shown in Figure 4. This
figure is valid only if RCLK or TCLK = 1 in T2CON. Note
that a rollover in TH2 does not set TF2 and will not gener-
ate an interrupt. Note too, that if EXEN2 is set, a 1-to-0
transition in T2EX will set EXF2 but will not cause a reload
from (RCAP2H, RCAP2L) to (TH2, TL2). Thus when Timer
2 is in use as a baud rate generator, T2EX can be used as
an extra external interrupt.
Note that when Timer 2 is running (TR2 = 1) as a timer in
the baud rate generator mode, TH2 or TL2 should not be
read from or written to. Under these conditions, the Timer is
incremented every state time, and the results of a read or
write may not be accurate. The RCAP2 registers may be
read but should not be written to, because a write might
overlap a reload and cause write and/or reload errors. The
timer should be turned off (clear TR2) before accessing the
Timer 2 or RCAP2 registers.
Modes 1 and 3
-------------------------------------- -
Baud Rate
=
--------------------------------------------------------------------------------------------- -
32
×
[
65536
Oscillator Frequency
(
RCAP2H,RCAP2L
AT89LS53
)
]
13