SP232ACN-L Exar Corporation, SP232ACN-L Datasheet - Page 9

no-image

SP232ACN-L

Manufacturer Part Number
SP232ACN-L
Description
IC DVR/RCVR RS232 LP 16NSOIC
Manufacturer
Exar Corporation
Type
Transceiverr
Datasheets

Specifications of SP232ACN-L

Package / Case
16-SOIC (0.154", 3.90mm Width)
Number Of Drivers/receivers
2/2
Protocol
RS232
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Surface Mount
Operating Supply Voltage
5 V
Supply Current
3 mA
Operating Temperature Range
0 C to + 70 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1016-1020-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP232ACN-L
Manufacturer:
Exar
Quantity:
1 835
Part Number:
SP232ACN-L
Manufacturer:
SIPEX
Quantity:
20 000
Part Number:
SP232ACN-L/TR
Manufacturer:
SIPEX-Pb FREE
Quantity:
1 471
Part Number:
SP232ACN-L/TR
Manufacturer:
SIPEX
Quantity:
20 000
Figure 9. ESD Test Circuit for Human Body Model
with IEC1000-4-2 is that the system is required
to withstand an amount of static electricity when
ESD is applied to points and surfaces of the
equipment that are accessible to personnel during
normal usage. The transceiver IC receives most
of the ESD current when the ESD source is
applied to the connector pins. The test circuit for
IEC1000-4-2 is shown on Figure 10. There are
two methods within IEC1000-4-2, the Air
Discharge method and the Contact Discharge
method.
Figure 10. ESD Test Circuit for IEC1000-4-2
Date: 7/19/04
DC Power
Source
DC Power
Source
R
R
C
C
R
R
C
C
SW1
SW1
SP202E Series High Performance RS232 Transceivers
SW1
SW1
C
C
S
S
9
R S and R V add up to 330Ω for IEC1000-4-2.
R S and R V add up to 330Ω for IEC1000-4-2.
With the Air Discharge Method, an ESD voltage
is applied to the equipment under test (EUT)
through air. This simulates an electrically charged
person ready to connect a cable onto the rear of
the system only to find an unpleasant zap just
before the person touches the back panel. The
high energy potential on the person discharges
through an arcing path to the rear panel of the
system before he or she even touches the system.
This energy, whether discharged directly or
through air, is predominantly a function of the
C
C
R
R
S
S
S
S
Contact-Discharge Module
Contact-Discharge Module
R
R
S
S
R
R
V
V
SW2
SW2
SW2
SW2
© Copyright 2004 Sipex Corporation
Device
Under
Test
Device
Under
Test