71M6513H-IGT/F Maxim Integrated Products, 71M6513H-IGT/F Datasheet - Page 49

no-image

71M6513H-IGT/F

Manufacturer Part Number
71M6513H-IGT/F
Description
IC ENERGY METER 3PH 100-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6513H-IGT/F

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6513H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
FUNCTIONAL DESCRIPTION
The energy delivered by a power source into a load can be expressed as:
Assuming phase angles are constant, the following formulae apply:
For a practical meter, not only voltage and current amplitudes, but also phase angles and harmonic content may change
constantly. Thus, simple RMS measurements are inherently inaccurate. A modern solid-state electricity meter IC such as the
71M6513/6513H functions by emulating the integral operation above, i.e. it processes current and voltage samples through an
ADC at a constant frequency. As long as the ADC resolution is high enough and the sample frequency is beyond the harmonic
range of interest, the current and voltage samples, multiplied with the time period of sampling will yield an accurate quantity for
the momentary energy. Summing up the momentary energy quantities over time will result in accumulated energy.
Figure 12 shows the shapes of V(t), I(t), the momentary energy and the total accumulated energy, resulting from 50 samples
of the voltage and current signals over a period of 20ms. The application of 240VAC and 100A results in an accumulation of
480Ws over the 20ms period, as indicated by the curve for Accumulated Energy.
The described sampling method works reliably, even in the presence of dynamic phase shift and harmonic distortion.
A Maxim Integrated Products Brand
P = Real Energy [Wh] = V * A * cos φ* t
Q = Reactive Energy [VARh] = V * A * sin φ * t
S = Apparent Energy [VAh] =
-100
-200
-300
-400
-500
500
400
300
200
100
0
Figure 12: Voltage. Current, Momentary and Accumulated Energy
0
Current [A]
Voltage [V]
Energy per Interval [Ws]
Accumulated Energy [Ws]
© 2005-2011 Teridian Semiconductor Corporation
P +
2
5
E
Theory of Operation
Q
=
2
0
t
V
) (
t
10
3-Phase Energy Meter IC
I
) (
t
dt
71M6513/71M6513H
15
DATA SHEET
time [ms]
20
SEPTEMBER 2011
Page: 49 of 104

Related parts for 71M6513H-IGT/F