X09-009PKC-RA Digi International/Maxstream, X09-009PKC-RA Datasheet

no-image

X09-009PKC-RA

Manufacturer Part Number
X09-009PKC-RA
Description
MOD RF 900MHZ 9600BPS RS232/485
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-009PKC-RA

Function
Transceiver, FHSS
Modulation Or Protocol
FHSS, FSK
Frequency
900MHz
Applications
ISM
Interface
RS-232, RS-485
Sensitivity
-110dBm
Power - Output
20dBm (100mW)
Data Rate - Maximum
10 kbps
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
XStream-PKG-R™ RS-232/485 RF Modem
Product Manual
For XStream RF Modem Part Numbers:
900 MHz & 2.4 GHz Stand-alone RF Modems by MaxStream, Inc.
355 South 520 West, Ste. 180
Lindon, UT 84042
Phone: (801) 765-9885
Fax: (801) 765-9895
rf-xperts@maxstream.net
www.maxstream.net
XStream RS-232/485 RF Modem
Interfacing Protocol
RF Modem Operation
RF Modem Configuration
RF Communication Modes
Appendices
v5.x00
X09-001PK…-R…
X09-009PK…-R…
X09-019PK…-R…
X24-009PK…-R...
X24-019PK…-R…
XH9-001PK…-R...
XH9-009PK…-R…
XH9-019PK…-R…
M100019
2006.02.24

Related parts for X09-009PKC-RA

X09-009PKC-RA Summary of contents

Page 1

... MHz & 2.4 GHz Stand-alone RF Modems by MaxStream, Inc. 355 South 520 West, Ste. 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 rf-xperts@maxstream.net www.maxstream.net X09-001PK…-R… X24-009PK…-R... X09-009PK…-R… X24-019PK…-R… X09-019PK…-R… XH9-001PK…-R... XH9-009PK…-R… XH9-019PK…-R… M100019 2006.02.24 ...

Page 2

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  © 2006 MaxStream, Inc. All rights reserved The contents of this manual may not be transmitted or reproduced in  any form or by any means without the written permission of  MaxStream, Inc.   XStream™ is a trademark of MaxStream, Inc.      Technical Support  Phone: (801) 765‐9885  Live Chat: www.maxstream.net   E‐Mail: rf‐xperts@maxstream.net   © 2006 MaxStream, Inc. Confidential & Proprietary                 ii  ...

Page 3

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Contents  1. XStream RS-232/485 RF Modem 1.1. Features 4 1.1.1. Worldwide Acceptance 1.2. Specifications 5 1.3. External Interface 6 2. Interfacing Protocol 2.1. RS-232 Operation 7 2.1.1. DIP Switch Settings and Pin Signals 2.2. RS-485 (2-wire) Operation 9 2.2.1. ...

Page 4

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  1. XStream RS‐232/485 RF Modem  The XStream-PKG-R RF Modem provides long range data communications and advanced networking for OEMs and system integrators. Out-of-box, the modem is equipped to sustain long range wireless links between devices. Simply enter serial data into one modem ...

Page 5

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  1.2. Specifications Table 1.1. XStream‐PKG‐R RS‐232/485 RF Modem Specifications    Specification 9XStream-PKG-R (900 MHz) Performance Indoor/Urban Range Up to 1500’ (450 miles (11 km) w/ dipole antenna Outdoor LOS Range miles (32 km) w/ high-gain antenna Transmit Power ...

Page 6

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  1.3. External Interface Figure 1.1. Front View  1.1a.  1.1c. DB‐9  Power  Serial Port  Switch  1.1b. I/O &  Power LEDs  Figure 1.2. Back View  1.2b.        Config Switch  1.2a.         1.2c.         DIP Switch  Antenna Port  Figure 1.3. DIP Switch Settings  © 2006 MaxStream, Inc. Confidential & Proprietary  1.1a. Power Switch Move the Power Switch to the on (up) position to power the Interface ...

Page 7

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  2. Interfacing Protocol  The XStream-PKG-R RF Modem supports the following interfacing protocols: • RS-232 • RS-485 (2-wire) Half-Duplex • RS-485 (4-wire) and RS-422 2.1. RS-232 Operation 2.1.1. DIP Switch Settings and Pin Signals Figure 2.1.  RS‐232 DIP Switch Settings        DIP Switch settings are read and applied  only while powering‐on.  ...

Page 8

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Wiring Diagram: RS-232 DTE Device to a DCE RF Modem Figure 2.3.   RS‐232 DTE (male connector) device wired to an XStream RF Modem (female connector)     Wiring Diagram: DCE RF Modem to an RS-232 DCE Device Figure 2.4.   XStream RF Modem (female connector) wired to an RS‐232 DTE (male connector) device  Sample Wireless Connection: DTE Figure 2.5.   Typical wireless link between DTE and DCE devices  © 2006 MaxStream, Inc. Confidential & Proprietary  DCE DCE DCE                8  ...

Page 9

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  2.2. RS-485 (2-wire) Operation 2.2.1. DIP Switch Settings and Pin Signals Figure 2.6.  RS‐485 (2‐wire) Half‐Duplex    DIP Switch Settings  Figure 2.8.  RS‐485 (2‐wire) with Termination (optional)  Termination is the 120 Ω resistor between T+ and T-. DIP Switch settings are read and applied only while powering-on. Note: Refer ...

Page 10

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  2.3. RS-485 (4-wire) & RS-422 Operation 2.3.1. DIP Switch Settings and Pin Signals Figure 2.10.  RS‐485 (4‐wire) and RS‐422    DIP Switch Settings  Figure 2.12.  RS‐485 (4‐wire) & RS‐422 with Termination (optional)  Termination is the 120 Ω resistor between T+ and T-. DIP Switch settings are read and applied only while powering-on. ...

Page 11

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Wiring Diagram: RS-422 Figure 2.14.    XStream RF Modem in an RS‐485 (4‐wire) environment  RS-485/422 Connection Guidelines The RS-485/422 protocol provides a solution for wired communications that can tolerate high noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as 4000 feet (1200 m). ...

Page 12

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  3. RF Modem Operation  3.1. Serial Communications 3.1.1. RS-232 and RS-485/422 Data Flow Devices that have a UART interface can connect directly through the pins of the XStream Modem as is shown in the figure below. Figure 3.1. System Data Flow Diagram in a UART‐interfaced environment   3.1.2. Host and ...

Page 13

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  3.1.3. Flow Control Figure 3.2. Internal Data Flow Diagram  DI (Data In) Buffer and Flow Control When serial data enters the XStream Modem through the DI Pin, then the data is stored in the DI Buffer until it can be transmitted. When the ...

Page 14

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  3.2. Modes of Operation XStream RF Modems operate in five modes. Figure 3.3. XStream Modes of Operation  Modem can only be in one mode at a time.  3.2.1. Idle Mode When not receiving or transmitting data, the modem is in Idle Mode. The modem uses the same amount of power in Idle ...

Page 15

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Figure 3.4. Data Transmission Sequence  RF Data Packet The RF packet is the sequence of data used for communicating information between MaxStream Modems Packet consists Initializer and RF Data. Figure 3.5. RF Data Packet Components  * When streaming multiple RF packets, ...

Page 16

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  3.2.3. Receive Mode If the modem detects RF data while in Idle Mode, the modem transitions into Receive Mode to receive RF packets. Once a packet is received, the modem checks the CRC to ensure that the data was ...

Page 17

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Pin Sleep ( Pin Sleep requires the least amount of power. In order to achieve this state, the DI3 (SLEEP) pin must be asserted (high). The modem remains in Pin Sleep until the DI3 pin is de-asserted. ...

Page 18

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Cyclic Scanning. Each RF transmission consists Initializer and payload. The wake-up initializer contains initialization information and all receiving modems must wake during the wake-up initializer portion of data transmission in order to be synchronized with the ...

Page 19

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  3.2.5. Command Mode To modify or read modem parameters, the modem must first enter into Command Mode, the state in which incoming characters are interpreted as commands. Two command types are available for programming the modem: • AT Commands ...

Page 20

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Binary Commands Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the XStream RF Modem. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts; or ...

Page 21

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  4. RF Modem Configuration  4.1. Automatic DIP Switch Configurations Each time the RF Modem is powered-on, intelligence on the XIB-R Interface Board (RS-232/485 interfacing board located inside the RF Modem) sends AT Commands that program the RF Modem based on positions ...

Page 22

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  4.2. Programming Examples For information about entering and exiting AT and Binary Command Modes, refer to the Command Mode section [p19]. 4.2.1. AT Commands MaxStream has provided X-CTU software for programming the modem using an extensive list of AT ...

Page 23

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  EXAMPLE: Restore RF Modem Defaults using the Terminal tab The following steps show how to read currently stored modem parameter values; then restore the modem parameters to their factory-default states. Method 1 (One line per command) Issue AT Command ...

Page 24

... Connection Inactivity Timeout CF v4.30* 0x35 (53d) Connection Failure Count CL v4.30* 0x39 (57d) Last Connection Address CM v4.30* 0x38 (56d) Connection Message CN 0x09 (9d) Exit AT Command Mode CO v4.30* 0x2F (47d) DO3 Timeout CS v4.27D* 0x1F (31d) DO2 Configuration CT 0x06 (6d) Command Mode Timeout DC v4.30* ...

Page 25

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  4.4. Command Descriptions Commands in this section are listed alphabetically. Command categories are designated between the “< >” symbols that follow each command title. XStream Modems expect numerical values in hexadecimal and those values are designated by a “0x” ...

Page 26

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  BK (Serial Break Passing) Command <Serial Interfacing> Pass a serial break condition on the DI pin to the DO pin of another modem. BO (Serial Break Timeout) Command <Serial Interfacing> DO pin will return to default after no serial ...

Page 27

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  CD (DO3 Configuration) Command <Command Mode Options> CD Command is used to redefine the behavior of the DO3 (Data Output 3)/RX LED line. CE (Connection Inactivity Timeout) Command <Networking & Security> Set/Read the duration of inactivity that will cause ...

Page 28

... the remote modem will send a “Disconnect Request Packet” to the base modem. © 2006 MaxStream, Inc. Confidential & Proprietary  AT Command: ATCN Binary Command: 0x09 (9 decimal) AT Command: ATCO Binary Command: 0x2F (47 decimal) Parameter Range: 0 – 0xFFFF [x 1 second] Default Parameter Value: 3 ...

Page 29

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  DR (DI3 Configuration) Command <Serial Interfacing> The DR Command is used to configure the DI3 (Data Input 3 / SLEEP) line for I/O line passing (use with and CO) or controlling connection status (use ...

Page 30

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  FH (Force Wake-up Initializer) Command <Sleep (Low Power)> FH Command is used to force a Wake-up Initializer to be sent on the next transmit. WR (Write) Command does not need to be issued with FH Command. Use only with ...

Page 31

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  HT (Time before Wake-up Initializer) Command <<Sleep (Low Power)> If any modems within range are running in a “Cyclic Sleep” setting, a wake-up initializer must be used by the transmitting modem for sleeping modems to remain awake [refer to ...

Page 32

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  LH (Wake-up Initializer Timer) Command <Sleep (Low Power)> LH Command adjusts the duration of time for which the RF initializer is sent. When receiving modems are put into Cyclic Sleep Mode, they power-down after a period of inactivity [specified ...

Page 33

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  MY (Source Address) Command <Networking & Security> Set/Read the source address of the modem. Refer to the Addressing section [p41] of the RF Communication Modes chapter for more information. NB (Parity) Command <Serial Interfacing> Select/Read parity settings for UART ...

Page 34

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  PW (Pin Wake-up) Command <Sleep (Low Power)> Under normal operation, a modem in Cyclic Sleep Mode cycles from an active state to a low-power state at regular intervals until data is ready to be received. If the PW Parameter ...

Page 35

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  RO (Packetization Timeout) Command <Serial Interfacing> RO Command is used to specify/read the time of silence (no bytes received) after which transmission begins. After a serial byte is received and if no other byte is received before the RO ...

Page 36

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  RS (RSSI) Command <Diagnostics> RS Command returns the signal level of the last packet received. This reading is useful for determining range characteristics of the XStream Modems under various conditions of noise and distance. Once the command is issued, ...

Page 37

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  SL (Serial Number Low) Command <Diagnostics> Set/Read the serial number low word of the modem. SM (Sleep Mode) Command <Sleep Mode (Low Power)> SM Command is used to adjust Sleep Mode settings. By default, Sleep Mode is disabled and ...

Page 38

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  SY (Time before Initialization) Command <Networking> SY Command keeps a communication channel open as long as modem transmits or receives before the active connection expires. It can be used to reduce latency in a query/response sequence and should be ...

Page 39

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  TT (Streaming Limit) Command <Networking> TT Command defines a limit on the number of bytes that can be sent out before a random delay is issued. TT Command is used to simulate full-duplex behavior modem is sending ...

Page 40

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5. RF Communication Modes  Network configurations covered in this chapter are described in terms of the following: • Network Topology (Point-to-Point, Point-to-Multipoint or Peer-to-Peer) • RF Communication Type (Basic or Acknowledged) • RF Mode (Streaming, Repeater, Acknowledged or Multi-Streaming) The following ...

Page 41

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5.1. Addressing Each RF packet contains addressing information that is used to filter incoming RF data. Receiving modems inspect the Hopping Channel (HP parameter), Vendor Identification Number (ID parameter) and Destination Address (DT parameter) contained in each RF packet. ...

Page 42

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5.2. Basic Communications Basic Communications are accomplished through two sub-types: • Broadcast - By default, XStream Modems communicate through Broadcast communications and within a peer-to-peer network topology. When any modem transmits, all other modems within range will receive the ...

Page 43

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5.2.2. Repeater Mode Characteristics: Constraints: Required Parameter Values (TX Modem unique value (can be accomplished by issuing the AM (Auto-set MY) and WR (Write) commands to all modems in the network) Related ...

Page 44

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Repeater Network Configuration A network may consist of End Nodes (EN), End/Repeater Nodes (ERN) and a Base Node (BN). The base node initiates all communications. The repeater network can be configured to operate using Basic Broadcast or Basic Addressed ...

Page 45

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Response packet delay As a packet propagates through the repeater network, if any node receives the data and generates a quick response, the response needs to be delayed so as not to collide with subsequent retransmissions of the original ...

Page 46

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5.3. Acknowledged Communications 5.3.1. Acknowledged Mode Characteristics: Recommended Use: Acknowledge Mode configuration is appropriate when reliable delivery is required between modems. If messages are smaller than 256 bytes, use RB and RO commands to align RF packets with application ...

Page 47

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  After receiving and acknowledging a packet, the receiving modem will move to the next frequency and listen for either a retransmission or new data for a specific period of time. Even if the transmitting modem has indicated that it ...

Page 48

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  5.3.2. Multi-Streaming Mode Characteristics: definition] Required Parameter Values (TX Modem (Base (Remote), RN > > ≠ 0xFFFF Recommended Use: Use this mode in point-to-multipoint networks where remote modems initiate ...

Page 49

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Initiating a Connection Connection Guidelines: • A remote modem can only request a connection with the base modem. • The base modem may hold off or grant a connection request to another modem. • A remote modem will not ...

Page 50

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Configuration AT Command Mode AT command mode is used for all commands on base and remote modems. Binary command mode is not available when The base command mode when not engaged ...

Page 51

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Sleep Modes and Connections Cyclic sleep can be used with the remote modems to conserve power. ST “Time before Sleep” Parameter defines how long after a disconnect a remote will stay awake. A modem is not allowed to enter ...

Page 52

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Appendix A:  Agency Certifications  FCC Certification The XStream RF Modem complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. To fulfill the FCC Certification requirements, the OEM must ...

Page 53

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  OEM Labeling Requirements Label Warning WARNING Figure A.1. Contains FCC ID: OUR9XSTREAM The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and ...

Page 54

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  FCC-Approved Antennas Table A.1. Antennas approved for use with 9XStream (900 MHz) RF Modems.  Manufacturer Part Number * * * * MaxStream A09- MaxStream A09-Y11 (FCC pending) MaxStream A09-F2 MaxStream A09-F5 MaxStream A09- MaxStream A09-M7 MaxStream A09-H MaxStream A09-HBMM-P5I MaxStream A09-QBMM-P5I ...

Page 55

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  European Compliance (2.4 GHz only) The 24XStream has been certified for use in several European countries. For a complete list, refer to http://www.maxstream.net. If the 24XStream modems are incorporated into a product, the manufacturer must ensure compliance of the ...

Page 56

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Notifications and Required Information Since the 2.4 GHz band is not harmonized throughout Europe, a notification must be sent to each country prior to shipping product according to Article 6.4 of the R&TTE Directive. A list of national contacts ...

Page 57

... For example: Part number “X09-019PKC-RA” includes the listed accessories and part number “X09-019PKC-R” does not. The accessories kit includes hardware and software needed for developing long range wireless links. For testing the modem’s range, MaxStream recommends the purchase of one RF Modem with the accessories and one without. Table  ...

Page 58

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Adapters The XStream Development Kit comes with several adapters that support the following functions: • Performing Range Tests (Serial Loopback) • Connecting to other RS-232 DCE and DTE devices (Male-to-Male NULL modem) • Testing Cables (Female-to-Female NULL modem) • ...

Page 59

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Antennas [Refer to Appendix A for a list of FCC-Approved Antennas] Factors that determine wireless link range: • Ambient RF noise (interference) • Line-of-sight obstructions • Transmit power • Receive sensitivity • Antenna configuration • XStream Antenna Connector Options ...

Page 60

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Appendix C:  Additional Information  1-Year Warranty XStream RF Modems from MaxStream, Inc. (the ʺProductʺ) are warranted against defects in materials  and workmanship under normal use, for a period of 1‐year from the date of purchase. In the event of  a product failure due to materials or workmanship, MaxStream will repair or replace the defective  product. For warranty service, return the defective product to MaxStream, shipping prepaid, for  prompt repair or replacement.  The foregoing sets forth the full extent of MaxStreamʹs warranties regarding the Product. Repair or  replacement at MaxStreamʹs option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU  OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND MAXSTREAM SPECIFICALLY  DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR  PURPOSE. IN NO EVENT SHALL MAXSTREAM, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR  DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE,  LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR  OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE  OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY  LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  CONSEQUENTIAL DAMAGES. THEREFOR, THE FOREGOING EXCLUSIONS MAY NOT APPLY  IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to  state may also apply.  Ordering Information Figure C.1    MaxStream RF Modem Part Numbers Key  © 2006 MaxStream, Inc. Confidential & Proprietary                 60  ...

Page 61

XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24]  Contact MaxStream Free and unlimited technical support is included with every MaxStream Radio Modem sold. Please use the following resources for additional support: Documentation: Technical Support: MaxStream office hours are 8:00 am – 5:00 pm [U.S. Mountain Standard Time] ...

Related keywords