4. RF Modem Configuration
4.1. Automatic DIP Switch Configurations
Each time the RF modem is powered-on, AT commands are sent to the on-board module as dic-
tated by the positions of the DIP switches. DIP switch configurations are sent automatically during
the power-on sequence and affect modem parameter values as shown in the table below.
Figure 4‐01. RF Modem DIP Switches
Table 4‐01. Power‐up Options ‐ Commands sent as result of DIP Switch Settings (SW = DIP Switch)
IMPORTANT: To avoid overwriting previously stored custom configurations (due to the automatic con-
figurations that take place each time the RF modem is powered-on), it is necessary to disable a pro-
cessor located inside the modem.
To disable the processor, turn switches 5 and 6 ON (up). When switches 5 and 6 are ON, only the
CS command is sent [refer to table below].
Table 4‐02. User Defined Mode (Switches 5 and 6 are ON (up))
Note: The results of SW 2, 5 & 6 ON and SW 5 & 6 ON are the same.
Switches
Switches 1 & 2
(Restore Defaults /
Serial Interfacing)
Switches 5 & 6
(TX/RX Modes)
© 2007 MaxStream, Inc.
Only DIP Switches ON (up)
SW1, SW5 and SW6
SW2, SW5 and SW6
SW5 and SW6 only
Condition
If SW1 & SW2 are
ON (up)
If SW1 is ON (up)
If SW1 is OFF (down)
If SW5 & SW6 are
OFF (down)
If SW5 is OFF (down)
& SW6 is ON (up)
If SW5 is ON (up) &
SW6 is OFF (down)
If SW5 is ON (up) &
SW6 is ON (up)
Condition
If CS = 0, 1, 2 or 4
If CS = 3
If CS = 2
If CS = 0, 1, 3 or 4
If CS = 2
If CS = 0, 1, 3 or 4
Behavior
Restore Defaults
RS-232 Operation
RS-485 or RS-422
Operation
Multipoint Base
Multipoint Remote
Point-to-Point
User Defined
Command Sent During Power-up
CS parameter remains the same
ATCS 0
ATCS 2
ATCS 3
ATCS 2
ATCS 3
Commands Sent During Power-up
ATRE
ATWR
ATCS 0
ATCS 3
ATMY 0
ATDT FFFF
ATMT 3
ATAM
ATDT 0
ATMT 0
ATRR A
ATAM
ATDT FFFF
ATMT 3
Processor is disabled and AT Commands are not sent to
the modem (except for CS command as shown below.)
(RS-232 operation, CTS flow control)
(GPO1 high)
(RS-485/422 Operation)
(GPO1 high)
(RS-485/422 Operation)
(Restore Defaults)
(Write defaults to non-volatile memory)
(RS-232, CTS flow control)
(RS-485 or RS-422 Operation)
(Source Address)
(Destination Address)
(Multi-Transmit option)
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
(Retries)
(Auto-set MY, MY = unique)
(Destination Address)
(Multi-Transmit option)
     22