XBP24-AUI-001 Digi International/Maxstream, XBP24-AUI-001 Datasheet - Page 25

no-image

XBP24-AUI-001

Manufacturer Part Number
XBP24-AUI-001
Description
MODULE 802.15.4 100MW U.FL CON
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-AUI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Command Mode
AT Command Mode
To modify or read RF Module parameters, the module must first enter into Command Mode - a
state in which incoming characters are interpreted as commands. Two Command Mode options are
supported: AT Command Mode [refer to section below] and API Command Mode [p57].
To Enter AT Command Mode:
Default AT Command Mode Sequence (for transition to Command Mode):
All of the parameter values in the sequence can be modified to reflect user preferences.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the
‘Baud’ setting on the “PC Settings” tab matches the interface data rate of the RF module. By default,
the BD parameter = 3 (9600 bps).
To Send AT Commands:
Figure 2‐08. Syntax for sending AT Commands 
To read a parameter value stored in the RF module’s register, omit the parameter field.
The preceding example would change the RF module Destination Address (Low) to “0x1F”. To store
the new value to non-volatile (long term) memory, subsequently send the WR (Write) command.
For modified parameter values to persist in the module’s registry after a reset, changes must be saved
to non-volatile memory using the WR (Write) Command. Otherwise, parameters are restored to previ-
ously saved values after the module is reset.
System Response. When a command is sent to the module, the module will parse and execute
the command. Upon successful execution of a command, the module returns an “OK” message. If
execution of a command results in an error, the module returns an “ERROR” message.
To Exit AT Command Mode:
For an example of programming the RF module using AT Commands and descriptions of each config-
urable parameter, refer to the RF Module Configuration chapter [p26].
Send the 3-character command sequence “+++” and observe guard times before and after the
command characters. [Refer to the “Default AT Command Mode Sequence” below.]
Send AT commands and parameters using the syntax shown below.
1.
2.
© 2009 Digi Internatonal, Inc.
• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]
• Input three plus characters (“+++”) within one second [CC (Command Sequence Character)
• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]
parameter = 0x2B.]
Timeout) Command, the RF module automatically returns to Idle Mode.
Send the ATCN (Exit Command Mode) command (followed by a carriage return).
If no valid AT Commands are received within the time specified by CT (Command Mode
[OR]
     25