Specifications of XBP24-AUI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
CC (Command Sequence Character) Command
CE (Coordinator Enable) Command
CH (Channel) Command
CN (Exit Command Mode) Command
CT (Command Mode Timeout) Command
<AT Command Mode Options> The CC command
is used to set and read the ASCII character used
between guard times of the AT Command Mode
Sequence (GT + CC + GT). This sequence enters
the RF module into AT Command Mode so that
data entering the module from the host is recog-
nized as commands instead of payload.
The AT Command Sequence is explained further in the AT Command Mode section.
<Networking {Association} The CE command is
used to set and read the behavior (End Device vs.
Coordinator) of the RF module.
<Networking {Addressing}> The CH command is
used to set/read the operating channel on which
RF connections are made between RF modules.
The channel is one of three addressing options
available to the module. The other options are the
PAN ID (ID command) and destination addresses
(DL & DH commands).
In order for modules to communicate with each
other, the modules must share the same channel number. Different channels can be used to pre-
vent modules in one network from listening to transmissions of another. Adjacent channel rejec-
tion is 23 dB.
The module uses channel numbers of the 802.15.4 standard.
Refer to the XBee/XBee-PRO Addressing section for more information.
<AT Command Mode Options> The CN command
is used to explicitly exit the RF module from AT
Command Mode.
<AT Command Mode Options> The CT command
is used to set and read the amount of inactive
time that elapses before the RF module automati-
cally exits from AT Command Mode and returns to
Idle Mode.
Use the CN (Exit Command Mode) command to
exit AT Command Mode manually.
© 2009 Digi Internatonal, Inc.
Center Frequency = 2.405 + (CH - 11d) * 5 MHz
AT Command: ATCN
AT Command: ATCC
Parameter Range: 0 - 0xFF
Default Parameter Value: 0x2B (ASCII “+”)
Related Command: GT (Guard Times)
AT Command: ATCT
Parameter Range:2 - 0xFFFF
Default Parameter Value: 0x64 (100 decimal
(which equals 10 decimal seconds))
Number of bytes returned: 2
Related Command: CN (Exit Command Mode)
AT Command: ATCH
Parameter Range: 0x0B - 0x1A (XBee)
Default Parameter Value: 0x0C (12 decimal)
Related Commands: ID (PAN ID), DL
(Destination Address Low, DH (Destination
Address High)
AT Command: ATCE
Parameter Range:0 - 1
Default Parameter Value:0
Minimum Firmware Version Required: v1.x80
Parameter
(d = decimal)
0
1
[x 100 milliseconds]
0x0C - 0x17 (XBee-PRO)
Configuration
Coordinator
End Device