X09-009NSC Digi International/Maxstream, X09-009NSC Datasheet - Page 24

no-image

X09-009NSC

Manufacturer Part Number
X09-009NSC
Description
MOD RF 900MHZ 9600BPS W/RPSMA
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of X09-009NSC

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
DR (DI3 Configuration) Command
DT (Destination Address) Command
E0 (Echo Off) Command
E1 (Echo On) Command
ER (Receive Error Count) Command
<Serial Interfacing> DR Command is used to
configure DI3 (pin 2, SLEEP) for I/O line passing
(use with CD = 1 or 2 and CO) or controlling
connection status (use with MD = 1 or 2).
<Networking & Security> DT Command is used
to set the networking address of an XStream
Module. XStream Modules use three filtration
layers: Channels (ATHP), Vendor Identification
Number (ATID) and Destination Addresses
(ATDT). DT Command assigns an address to a
module that enables it to communicate only with
other modules having the same addresses. All
modules that share the same Destination Address can communicate freely with each other.
Modules in the same network with a different Destination Address (than that of the transmitter)
will listen to all transmissions to stay synchronized, but will not send any of the data out their
serial ports.
<Command Mode Options> The E0 command
turns off character echo in AT Command Mode.
By default, echo is off.
<Command Mode Options> E1 Command turns
on the echo in AT Command Mode. Each typed
character will be echoed back to the terminal
when ATE1 is active. E0 is the default.
<Diagnostics> Set/Read the receive error count.
The error-count records the number of packets
partially received then aborted on reception
error. This value returns to 0 after a reset and is
not non-volatile (value does not persist in the
module’s memory after a power-up sequence).
Once the receive error count reaches its
maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count
value is explicitly changed or the module is reset.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATDR
Binary Command: 0x2D (45 decimal)
Parameter Range: 0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CD (DO3 Configuration),
CO (DO3 Timeout), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATDT
Binary Command: 0x00
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping Channel), ID
(Module VID), MK (Address Mask)
AT Command: ATE0
Binary Command: 0x0A (10 decimal)
AT Command: ATE1
Binary Command: 0x0B (11 decimal)
AT Command: ATER
Binary Command: 0x0F (15 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: GD (Receive Good Count)
Parameter
0
1
2
3
4
DI3 I/O passing enabled
Connect and Disconnect
Disconnect on high
Connect on low
Configuration
Disabled
24 

Related parts for X09-009NSC