X09-009NSC Digi International/Maxstream, X09-009NSC Datasheet - Page 27

no-image

X09-009NSC

Manufacturer Part Number
X09-009NSC
Description
MOD RF 900MHZ 9600BPS W/RPSMA
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of X09-009NSC

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
LH (Wake-up Initializer Timer) Command
MD (RF Mode) Command
MK (Address Mask) Command
<Sleep (Low Power)> Set/Read the amount of
time during which the RF initializer is sent. When
receiving modules are put into Cyclic Sleep Mode,
they power-down after a period of inactivity
[specified by ST (Time before Sleep) Command]
and will periodically awaken and listen for
transmitted data. In order for the receiving
modules to remain awake, they must detect
~35ms of the wake-up initializer.
LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens
the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up
Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode)
Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection
would be at risk of missing the wake-up initializer transmission.
Refer to the figures in the Sleep Mode sections [p13] to view correct and incorrect configuration
diagrams. The images help visualize the importance that the LH value be greater than the SM cyclic
sleep value.
<Networking & Security> The MD command is
used to select/read the RF Mode (Peer-to-peer,
Multi-Stream or Repeater Modes) of the module.
Multi-Streaming Mode enables exclusive
connections in point-to-multipoint networks.
Refer to the Multi-Streaming Mode section [p43]
for more information regarding how these
parameter values affect other parameter values.
Repeater Mode enables longer range via an
intermediary module. When MD=3, the module
will act as a “store and forward” repeater. Any
packets not addressed to this node will be
repeated. A Repeater End Node (MD=4) handles
repeated messages, but will not forward the data
over-the-air. Refer to the Repeater Mode section
[p38] for more information.
<Networking & Security> MK Command is used
to set/read the address mask of the module.
All data packets contain the destination address
(DT Parameter) of the transmitting module.
When an RF data packet is received, the
transmitter’s destination address is logically
“ANDed” (bitwise) with the Address Mask of the
receiver. The resulting value must match the
destination address or the address mask of the
receiver for the packet to be received and sent
out the module DO serial port. If the “ANDed”
value does not match either the destination address or the address mask of the receiver, the
packet is discarded. (All “0” values are treated as “irrelevant” values and are ignored.)
Refer to the Addressing Options section [p36] for more information.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATMD
Binary Command: 0x32 (50 decimal)
Parameter Range: 0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
CM (Connection Message), DC (Disconnect)
Minimum Firmware Version Required: 4.30
AT Command: ATLH
Binary Command: 0x0C (12 decimal)
Parameter Range: 0 – 0xFF
Default Parameter Value: 1
Number of bytes returned: 1
Related Commands: HT (Time before Wake-up
Initializer), SM (Sleep Mode), ST (Time before
Sleep)
AT Command: ATMK
Binary Command: 0x12 (18 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0xFFFF
(Destination address (DT parameter) of the
transmitting module must exactly match the
destination address of the receiving module.)
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Module VID), MY
(Source Address)
Parameter
0
1
2
3
4
[x 100 milliseconds]
(transparent operation)
Multi-Stream Remote
Repeater & End Node
Multi-Stream Base
Configuration
Peer-to-Peer
End Node
27 