X09-019NSC-TX Digi International/Maxstream, X09-019NSC-TX Datasheet - Page 16

no-image

X09-019NSC-TX

Manufacturer Part Number
X09-019NSC-TX
Description
MOD RF TX 900MHZ 19.2K W/RPSMA
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019NSC-TX

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
2.2.5. Command Mode
AT Commands
To Enter AT Command Mode:
To Send AT Commands:
To Exit AT Command Mode:
To modify or read module parameters, the module must first enter into Command Mode (a state
in which incoming characters are interpreted as commands). Two command types are supported:
1.
2.
Default AT Command Mode Sequence (for transitioning to Command Mode):
Send AT commands and parameters using the syntax shown below.
Figure 2‐10. Syntax for sending AT Commands 
The preceding example would change the module Destination Address to “0x1F”. For modified
parameter values to persist in the module registry, changes must be saved to non-volatile
memory using WR (Write) Command. Otherwise, parameters are restored to previously saved
values after the module is powered off and then on again.
NOTE: To read the current value of a module parameter, leave the parameter field blank. For
example, the following command will return the current destination address: ATDT<CR>
System Response. When a command is sent to the module, the module will parse and execute
the command. Upon successful execution of a command, the module returns an “OK” message. If
execution of a command results in an error, the module returns an “ERROR” message.
1.
2.
For an example that illustrates programming the module using AT Commands, refer to the
Module Configuration chapter [p18].
   © 2006 MaxStream, Inc. Confidential and Proprietary 
• AT Commands
• Binary Commands
• No characters sent for one second [BT (Guard Time Before) parameter = 0x0A]
• Input three plus characters (“+++”) within one second [CC (Command Sequence Character)
• No characters sent for one second [AT (Guard Time After) parameter = 0x0A]
Send the 3-character command sequence “+++” and observe guard times before and after
the command characters. [Refer to the “Default AT Command Mode Sequence” below.] The
“Terminal” tab (or other serial communications software) of the X-CTU Software can be used
to enter the sequence.
[OR]
Assert (low) the
(If using a MaxStream XIB-R Interface Board, the same result can be achieved by keeping
the configuration switch pressed while turning off, then on again the power supplying the
module assembly (module assembly = module mounted to an interface board))
Send ATCN (Exit Command Mode) Command.
[OR]
If no valid AT Commands are received within the time specified by CT (Command Mode
Timeout) Command, the Module automatically returns to Idle Mode.
Command = 0x2B-0]
pin and either turn the power going to the module off and back on.
16 