E8MS-01 Omron, E8MS-01 Datasheet

no-image

E8MS-01

Manufacturer Part Number
E8MS-01
Description
SENSOR PRESSURE POSITIV 0-100KPA
Manufacturer
Omron
Series
E8MSr
Datasheet

Specifications of E8MS-01

Pressure Type
Gauge
Operating Pressure
14.50 PSI, 100 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Mounting Style
Desktop
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
12 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8MS01
Four-channel Input Controller for
Control of Multiple Sensor Heads
Ordering Information
Sensors
E8MS
* Do not connect the E8MS-N1 to a Controller. A Controller is not necessary.
E8M
Controllers
* The E8M-MP8 cannot be connected to the E8MS-N1.
Positive pressure
Negative pressure
Compound pressure
Minute pressure
differential
Positive pressure
Negative pressure
Power supply voltage
Pressure Sensor
E8MS/E8M
Be sure to read Safety Precautions on
page 12.
24 VDC
Pressure range
Pressure range
Differential pressure from 0 to 1,000 Pa
between positive and negative ports
Output configuration
NPN open collector
−101 to 101 kPa
0 to −101 kPa
0 to −101 kPa
0 to 100 kPa
0 to 1 MPa
0 to 1 MPa
Number of sensor inputs
Output configuration
Output configuration
Linear output: 1 to 5 V
Linear output: 1 to 5 V
4
CH
CSM_E8MS_E8M_DS_E_3_1
E8MS-01
E8MS-10
E8MS-N0
E8MS-N1
E8M-A1-S
E8M-10
E8M-N0
K3C-MP8
Model
Model
Models
*
*
1

Related parts for E8MS-01

E8MS-01 Summary of contents

Page 1

... MPa 0 to −101 kPa −101 to 101 kPa MPa 0 to −101 kPa Output configuration Number of sensor inputs NPN open collector CSM_E8MS_E8M_DS_E_3_1 Output configuration Model E8MS-01 E8MS-10 Linear output E8MS-N0 E8MS-N1 * Output configuration Model E8M-A1-S Linear output E8M-10 E8M-N0 Models ...

Page 2

... One Adapter is attached to Y92F-37-S the E8M-MP8 Controller. Hard Protective Front Cover Appearance Model Y92A-40-S Sensor and Controller Combinations Use the Pressure Controllers in the following combinations. The E89-M3/M4 is required when using the Sensor as a single unit. Model E89-M3-S E8MS-01 No E8MS-10 No E8MS-N0 No E8MS- E8M-A1-S No ...

Page 3

... Ratings and Specifications Sensors E8MS Item Model E8MS-01 Power supply voltage 12 VDC ±10%, ripple (p- max. Current consumption 25 mA max. Pressure type Gauge pressure Applicable fluid Non-corrosive gas and non-flammable gas Rated pressure range 0 to 100 kPa Withstand pressure 400 kPa Linearity ± ...

Page 4

... MPa * ±5% FS max. ±0.12% FS/°C max times each and Z directions R (PT) 1/8 and M5 female screw Connector Approx Stainless steel (SUS304) Aluminum, polyether sulfonic resin Instruction manual E8MS/E8M E8M- −101 kPa 400 kPa times each for 8 min and Z directions M5 male screw Approx ...

Page 5

... Weight Approx (not including accessories) Accessories Instruction manual, Adapter, Water-proof Packing * Pressure differentials are displayed with a minus (−) sign. E8M-MP8 E8MS-10 E8MS-01 E8M- 100 kPa MPa times each for 8 min and Z directions (with 2 3 times each and Z directions (with power supplied) ...

Page 6

... Engineering Data (Typical) Linear Output Voltage vs. Pressure E8MS- 100 Pressure (kPa) E8M-A1 200 400 600 800 1,000 0 Differential pressure (Pa) between positive and negative ports E8MS-10/E8M- 200 400 600 800 1,000 0 Pressure (kPa) E8MS- −101 −60 − 101 Pressure (kPa) E8MS/E8M E8MS-N0/E8M-N0 ...

Page 7

... Output Linearity E8MS- −1 −2 −3 −4 − 100 Pressure (kPa) E8M- −1 −2 −3 −4 −5 0 200 400 600 800 1,000 Differential pressure (Pa) between positive and negative ports E8MS-10/E8M-10 5 E8MS-10 4 E8M- −1 −2 −3 −4 −5 0 200 400 600 800 ...

Page 8

... Linear Output Fluctuation vs. Voltage E8MS-01 0.5 0.4 0.3 0.2 Pressure 0 0.1 0 −0.1 Rated pressure −0.2 −0.3 −0.4 −0.5 10.5 11 11.5 12 12.5 13 13.5 Voltage (V) E8M-A1-S 0.5 0.4 0.3 0.2 Pressure 0 0.1 0 −0.1 −0.2 Rated pressure −0.3 −0.4 −0.5 10.5 11 11.5 12 12.5 13 13.5 ...

Page 9

... Linear Output Fluctuation vs. Temperature E8MS- Rated pressure 1 0 −1 Pressure 0 −2 −3 −4 −5 − Temperature (˚C) E8M-A1 Pressure Rated pressure −1 −2 −3 −4 −5 − Temperature (˚C) E8MS- Rated pressure (negative) Pressure −1 −2 Rated pressure (positive) −3 −4 − ...

Page 10

... I/O Circuit Diagrams Sensor Output configuration Model E8MS-01 E8MS-10 E8MS-N0 E8MS- E8M-A1-S linear output E8M-10 E8M-N0 Controller Output configuration Model NPN output E8M-MP8 Output circuit Connector Brown 3 +V Pressure Sensor main 2 Black (linear output) circuit Load Blue Brown +V Power indicator Pink * ...

Page 11

... Protective Front Cover . . . . . . . . . . . . . . . . . . . . . . . Y92A-40 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y92F-48-S (This Adapter is to mount the E8M-MP8 in the panel cutout dimensions for the K3C Series.) Water-proof Packing (Accessory) Protective Front Cover Adapter SET Button Panel Mounting Adapter (Accessory) E8MS/E8M Unit indicator (orange) Channel display (red) Down Button 11 ...

Page 12

... Precautions for Correct Use Do not use this product in atmospheres or environments that exceed product ratings. ● Installation Connecting and Locking the E8MS Sensor I/O Connector (E89-M4) (1)Hold both ends of the female connector connected to the Sensor I/O Connector so that the protrusion on the female connector faces ...

Page 13

... Sensor under the rated pressure. (5)Do not insert any wire into the pressure port. Doing so may damage the pressure elements and cause a malfunction. (6)Do not apply any tensile strength in excess of 20N for E8MS, 30N Flat-blade screwdriver for E8M to the cables or connectors. ...

Page 14

... Dimensions Main Unit Sensors E8MS-01 E8MS-10 M5 (depth: 7.5 mm) E8MS-N0 E8MS-N1 (15) E8M-A1-S 19 Note: One XN2A-1430 is supplied together with the E8M-A1-S. E8M-10 M8 hexagonal nut R1 Pressure port 13.5 16.7 (37.5) E8M-N0 M4 hexagonal nut M5 7 Pressure port 16.7 7 (31) Connector: DF13B-3P-1.25V (21) R (PT)1/8 by Hirose Electric Pressure port (8 ...

Page 15

... Controller E8M-MP8 (43.9) ------------------------------------------- ------------------------------------------- ------------------------------------------- ------------------------------------------- Accessories (Order Separately) Sensor I/O Connector For the E8M Only E89-M3-S Note: One XN2A-1430 is provided. with the E89-M3-S. For the E8MS Only E89-M4-S 8.9 Note: One XN2A-1430 is provided with the E89-M4-S. 53 (43.5) 47 40.1 (9.4) ( (42x42) (42.4x42.4) (46.4) Panel Mounting Adapter ...

Page 16

... Note: One Connector is provided with the E89-M3-S or E89-M4-S. Hard Protective Front Cover Y92A-40-S (17.8) 15 Display surface 3.5 48x48 2 37x37 E8MS/E8M 6 2 (pitch) 1 3.4 3.3 13.55 5.05 12.2 17.6 7.5 (strip gauge) 6 15.8 1.2 dia. (internal) 1.65 dia. (external) 1 ...

Page 17

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...