SX100GD2 Honeywell Sensing and Control, SX100GD2 Datasheet - Page 2

SENSOR HI-IMP 100PSIG DIP PKG

SX100GD2

Manufacturer Part Number
SX100GD2
Description
SENSOR HI-IMP 100PSIG DIP PKG
Manufacturer
Honeywell Sensing and Control
Series
SXr
Datasheets

Specifications of SX100GD2

Pressure Type
Gauge
Operating Pressure
100 PSI
Port Size
Male, 0.105" (2.67mm) Tube, Dual
Output
0 ~ 150mV
Voltage - Supply
12V
Operating Temperature
-40°C ~ 85°C
Package / Case
DIP
Sensor Output
Voltage
External Depth
13.84mm
Voltage Rating
12V
Port Style
Straight
Pressure Measurement Type
Gage
Operating Pressure Range
0-100 Psi
Output Type
Voltage
Operating Pressure Max
100psi
Operating Pressure Min
0psi
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
287-1075
Silicon Pressure Sensors
SX 0 psi to 1 psi to 0 psi to 150 psi
CHARACTERISTICS (Maximum Ratings For All Devices)
Supply Voltage, V
Operating Temperature Range
Storage Temperature Range
Humidity
Common-mode Pressure
Lead Soldering Temperature
PERFORMANCE CHARACTERISTICS
Characteristic Description
Zero Pressure Offset
Temperature Coefficient of Offset
Combined Pressure Non-Linearity, and Hysteresis
Long Term Stability of Offset and Span
Response Time
Input Resistance
Temperature Coefficient of Resistance
Temperature Coefficient of Span
Output Resistance
Repeatability
SX PERFORMANCE CHARACTERISTICS
SX01
SX05
SX15
SX30
SX100
SX150
Specification Notes:
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10: Exceeding maximum pressure can cause permanent sensor failure
2 Honeywell • Sensing and Control
Number
Part
Reference Conditions; T
The zero pressure offset is 0 mV minimum to -20 mV typical and 35 mV maximum for part numbers SXxxxGD2 and SXxxxDD4.
Slope of best straight line fit from 0°C to 70°C. For operation outside this temperature range, contact factory for more information.
This parameter is not 100% tested. It is guaranteed by process design.
Pressure Hysteresis - the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
Pressure Non-linearity the maximum deviation of measure output, at constant temperature (25 °C [77 °F]), from “best straight line” through
three points (offset pressure, full-scale pressure, one-half full scale pressure).
Long term stability over a one year period.
Response time for a 0 psi to Full-Scale Span pressure step change, 10% to 90% rise time.
Maximum difference in output at any pressure within the operating pressure range and the temperature range within 0 °C to 70 °C [32 °F to
158 °F] after:
Full-scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Full-scale span is
ratiometric to the supply voltage.
0 psi to 1 psi
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
0 psi to 150 psi
Pressure Range
(8)
a)
b)
Operating
(7)
S
100 temperature cycles, 0 °C and 70 °C [32 °F to 158 °F]
1 million pressure cycles, 0 psi to full-scale span.
(2)
A
= 25 °C [77 °F], Supply V
(3,4)
(3,4)
Sensitivity
(mV/V/psi)
0.75
0.15
Typ
4.0
3.0
1.5
0.3
(3,4)
(6)
12 Vdc
-40 °C to 85 °C [-40 °F to 185 °F]
-55 °C to 125 °C [-67 °F to 257 °F]
0 % to 100 % RH
150 psig
250 °C [482 °F] 2 sec to 4 sec
(1)
(1)
(5)
Min.
S
100
15
50
75
75
75
= 5 Vdc; Common Line Pressure = 0 psig, Pressure Applied to P1
-2550
-35.0
Full-Scale Span
Min.
690
(mV)
Typ.
110
110
150
110
20
75
-2150
-20.0
Typ.
100
750
0.2
0.1
4.1
4.1
0.5
(9)
4
Max.
100
150
150
200
150
25
(10)
-1900
Max.
±0.5
810
0.0
Pressure
150 psi
200 psi
20 psi
20 psi
45 psi
90 psi
Burst
SX Series
µV/V/°C
ppm/°C
ppm/°C
%FSS
%FSS
%FSS
Unit
mV
kΩ
kΩ
µs