ZC-D55 Omron, ZC-D55 Datasheet - Page 2

SWITCH LIMIT SPDT 10A

ZC-D55

Manufacturer Part Number
ZC-D55
Description
SWITCH LIMIT SPDT 10A
Manufacturer
Omron
Series
ZCr
Datasheets

Specifications of ZC-D55

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1200gf
Actuator Style
Plunger
Operating Force Max
11.8N
Contact Voltage Ac Max
480V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
10A
Switch Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ZCD55
Specifications
Approved Standards
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Note: 1. The above figures are for steady-state currents.
Characteristics
*1. Only for models with plungers. (Contact your OMRON representative for
*2. Less than 1 ms under a free state at the operating limits.
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Inrush
current
Degree of protections
Durability
Operating speed
Operating
frequency
Insulation resistance
Contact resistance
Dielectric
strength
Rated insulation voltage (Ui)
Pollution degree
(operating environment)
Short-circuit protective device
Protection against electric shock
Proof tracking index (PTI)
Switch category
Rated operating current (Ie)
Rated operating voltage (Ue)
Vibration
resistance
Shock
resistance
Ambient operating temperature
Ambient operating humidity
Weight
voltage
Rated
information on other models.)
TÜV Rheinland
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions
CCC(CQC)
constant of 7 ms max. (DC).
according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity:
(3) Operating frequency:20 operations/min.
Agency
UL*
10
10
10
10
Resistive load
NC
6
0.5
0.25
Non-inductive load (A)
Mechanical
Electrical
Mechanical
Electrical
Between non-continu-
ous terminals
Between each terminal
and non-current-carry-
ing metal parts
Malfunction
Destruction
Malfunction
NC
NO
NO
30 A max.
15 A max.
EN60947-1, EN60947-5-1
3
2.5
3
3
3
0.4
0.2
Lamp load
NC
65±5%RH
GB14048.5
Standard
UL508
1.5
1.25
1.5
1.5
1.5
0.4
0.2
NO
IP67
10,000,000 operations min.
500,000 operations min.
0.05 mm/s to 0.5 m/s *1
120 operations/min
20 operations/min
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value for the built-
in switch when tested alone)
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
1,000 VAC
3 (IEC947-5-1)
10 A-fuse type gG (IEC 60269)
Class II
175
D (IEC335)
10 A
250 VAC
10 to 55 Hz, 1.5-mm double ampli-
tude *2
1,000 m/s
300 m/s
(in case of plunger model) *1 *2
−10°C to +80°C (with no icing)
35% to 95%RH
Approx. 92 g (in case of ZC-
Q22(21)55)
10
10
Inductive load
NC
6
6
5
0.05
0.03
2
max.
Inductive load (A)
2
max.
NO
2003010303077620
J50041904
5
3
5
5
5
0.05
0.03
File No.
E76675
Motor load
NC
2.5
1.5
2.5
2.5
2.5
0.05
0.03
NO
Approved Standard Ratings
UL/CSA
A300
TÜVRheinland (EN60947-1, EN60947-5-1),
CCC (GB14048.5)
Engineering Data
Electrical Durability
Mechanical Durability (for ZC-Q55)
120 VAC
240 VAC
Voltage
Applicable category and ratings
AC-12 10 A/250 VAC
10,000
10,000
7,000
5,000
3,000
1,000
7,000
5,000
3,000
1,000
700
500
300
100
current
700
500
300
100
70
50
30
Carry
70
50
30
10
10A
0
0
0.1
2
Make
Operating temperature: +20±2°C
Operating humidity: 65±5%RH
Operating frequency: 20 operations/min
125 VAC cosφ=1
60
30
0.3 0.5 0.7 1
125 VAC cosφ=0.4
Current (A)
4
250 VAC cosφ=1
Operating temperature: +20 ± 2˚C
Operating humidity: 65 ± 5%RH
No load
Operating frequency: 120 operations/min
250 VAC cosφ=0.4
6
Break
6
3
Switching current (A)
8
3
Make
7,200
10
Volt-amperes
OT (mm)
5 7 10
ZC-@55
(VA)
12
Break
720
2

Related parts for ZC-D55