ZC-D55 Omron, ZC-D55 Datasheet - Page 7

SWITCH LIMIT SPDT 10A

ZC-D55

Manufacturer Part Number
ZC-D55
Description
SWITCH LIMIT SPDT 10A
Manufacturer
Omron
Series
ZCr
Datasheets

Specifications of ZC-D55

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1200gf
Actuator Style
Plunger
Operating Force Max
11.8N
Contact Voltage Ac Max
480V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
10A
Switch Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ZCD55
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Dog Angle
When operating the roller type, be sure to set the dog angle to less than
30
angle exceeding 30
twisting force to the plunger. Set the OT to 70% to 100% of the specified
value so that the actuator will not exceed the OT.
Handling
Rubber packing
• Seal material may deteriorate if a Switch is used outdoor or where
• Install Switches where they will not be directly subject to cutting
• Constantly subjecting a Switch to vibration or shock can result in
• The Switches have physical contacts. Using them in environments
• When detaching the Terminal
• When mounting the Terminal
• A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the
• Use weather-proof rubber (chloroprene rubber) as seal rubber for
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
containing silicon gas will result in the formation of silicon oxide
(SiO
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
°
Protective Cover, insert a
screwdriver and apply a force
in the opening direction. Do
not use excess force to
remove the cover. Doing so
may cause deformation in the
fitting section and reduce the
holding force.
Protective Cover to the case,
align the cover on the case and then press the cover down to mount
it firmly. If the cover is pressed down in an inclined position, rubber
packing will deform and thus affect the sealing capability.
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm
the ZC-N22(21)55.
Not Suitable
(even when operating at a low speed). Operating the model at a dog
2
) due to arc energy. If silicon oxide accumulates on the
Precautions for Correct Use
°
will soon cause abrasion or damage. Do not apply a
Suitable
Rubber packing
2
.)
Micro Load Models
Contact failure may occur is a General-purpose Switch is used to
switch a microload circuit. Use Switches within the areas shown in the
following chart. Even when using Microload Switches within the area
shown below, contact wear will become more extreme with loads that
generate surge current when switching and durability will be
adversely affected. If necessary, insert a contact protective circuit.
Microloads are indicated by N standard reference values. This value
represents the failure rate at a 60% (λ60) reliability level. (JIS C5003)
The equation λ60 = 0.5 × 10
of 1/2,000,000 operations can be expected at a reliability level of 60%.
Mounting
Appropriate Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
Operation
With the ZC-Q22(21)55, an
appropriate OT line is marked on
the plunger. Set the OT so that it is
between the two X-surface lines.
• When mounting the Switch with
• When mounting the Panel Mount-
Minimum applicable
No.
screws on a side surface, fasten the
Switch with M4 screws and use
washers, spring washers, etc., to
ensure secure mounting.
type Enclosed Switch (ZC-Q55, ZC-
Q2255, or ZC-Q2155) with screws
on a side surface, remove the
hexagonal nuts from the actuator.
(1)
(2)
(3)
Model
Terminal screw
Panel mounting screw
Side mounting screw
load
30
24
12
5
0
0.1
Not
applicable
Type
1 mA
1
5 VDC 1mA
−6
ZC-@55-01
Applicable area
for Microload
Models
(ZC- @ 55-01)
/operations indicates that a failure rate
10
0.8 W
26 mA
Appropriate Tightening
100 mA 160 mA
100 mA
100
0.78 to 1.18 N·m
4.90 to 7.84 N·m
1.18 to 1.47 N·m
Two, 4.3-dia. or M4 screw holes
Current (mA)
Applicable
area for
General-
purpose
Models
(ZC- @ 55)
Mounting Holes
Mounting Holes
Torque
5 VDC 160mA
25.4
1,000
ZC-@55
ZC-@55
±
0.15
14.5
+0.2
0
dia.
7