LPS52-M Emerson Network Power, LPS52-M Datasheet

no-image

LPS52-M

Manufacturer Part Number
LPS52-M
Description
Linear & Switching Power Supplies 60W 5V 11A
Manufacturer
Emerson Network Power
Datasheet

Specifications of LPS52-M

Commercial/medical
Medical
Output Power Rating
55 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
11 A
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
LPS50-M Series
60 Watts
Special Features
• Medical Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
• LED power good indicator
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• LPX50 enclosure kit available
• Dual AC fuses
Safety
Total Power:
Input Voltage:
# of Outputs:
protection
(CISPR 22 Class B)
UL:
CSA: CSA-C22.2 No. 601.1-M90
VDE: EN60601-1
CE:
UL 60601-1
LVD & EMC
55 - 60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input power:
Efficiency:
EMI/RFI:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 30-50% above nominal output
Remote sense:
90 - 264 VAC (wide range) 127-300 Vdc
47-440 Hz
< 60 A peak @ 230 VAC, cold start @ 25°C
< 74 Watts
80% - 85% typical at full load
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B
conducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
60W for convection (LPS52, 55 W)
±20% minimum
10/ 2 0 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Compensatesd for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 1.08.09_149
LPS50-M Series
1 of 3

Related parts for LPS52-M

LPS52-M Summary of contents

Page 1

... Efficiency: 80% - 85% typical at full load EMI/RFI: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted Safety ground leakage 275uA @ 50/60 Hz; 264 VAC input current: Output Maximum power: 60W for convection (LPS52 Adjustment range: ±20% minimum Hold-up time: 10 115/230 VAC input line Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating Overvoltage protection: 30-50% above nominal output Remote sense: Compensatesd for 0.5 V lead drop max. Will operate without remote sense connected ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 95% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing M1 GRN DB1 YEL TP1 GND SK1 T3.15A 2. 250VAC 2005 0.197” (5.0) Minimum ...

Page 3

... LPS52 LPS53 LPS54 LPS55 LPS58 Peak current lasting < 15 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Pin Assignments LPS52-M LPS53-M Connector SK1-1 Line Line SK1-3 Neutral Neutral SK2 +12 V SK2 +12 V SK2-3 Common Common SK2-4 Common ...

Related keywords