HSCSFFN005PDAA5 Honeywell, HSCSFFN005PDAA5 Datasheet

no-image

HSCSFFN005PDAA5

Manufacturer Part Number
HSCSFFN005PDAA5
Description
Board Mount Pressure Sensors 5V AXIAL PORT 5psi DIFFER SIP
Manufacturer
Honeywell
Datasheet

Specifications of HSCSFFN005PDAA5

Operating Pressure
+/- 5 psi
Pressure Type
Differential
Accuracy
+/- 0.25 %
Output Type
Analog - Voltage
Mounting Style
Through Hole
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
2 mA
Package / Case
SIP-4
Digital Output - Bus Interface
Analog Voltage
Digital Output - Number Of Bits
12
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DESCRIPTION
The TruStability High Accuracy Silicon Ceramic (HSC) Series
is a piezoresistive silicon pressure sensor offering a ratiometric
analog output for reading pressure over the specified full scale
pressure span and temperature range.
The HSC Series is fully calibrated and temperature
compensated for sensor offset, sensitivity, temperature effects,
and non-linearity using an on-board Application Specific
Integrated Circuit (ASIC). Calibrated output values for pressure
are updated at approximately 1 kHz.
The HSC Series is calibrated over the temperature range of
0 C to 50 C [32 F to 122 F]. The sensor is characterized for
operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
Industry-leading long-term stability
Extremely tight accuracy of 0.25% FSS BFSL (Full Scale
Span Best Fit Straight Line)
Total error band of 1% full scale span maximum
Modular and flexible design offers customers a variety of
package styles and options, all with the same industry-
leading performance specifications
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package
Low operating voltage
Extremely low power consumption
Ratiometric analog output
High resolution (min 0.03 %FSS)
These sensors measure absolute, differential, and gage
pressures. The absolute versions have an internal vacuum
reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The TruStability
non-corrosive, non-ionic gases, such as air and other dry
gases. An available option extends the performance of these
sensors to non-corrosive, non-ionic liquids.
All products are designed and manufactured according to ISO
9001 standards.
Precision ASIC conditioning and temperature compensated
over 0 C to 50 C [32 F to 122 F] temperature range
RoHS compliant
Virtually insensitive to mounting orientation
Internal diagnostic functions increase system reliability
Also available with I
Absolute, differential and gage types
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
Custom calibration available
Various pressure port options
Liquid media option
®
pressure sensors are intended for use with
2
C or SPI digital output

Related parts for HSCSFFN005PDAA5

HSCSFFN005PDAA5 Summary of contents

Page 1

... RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability 2 Also available with SPI digital output Absolute, differential and gage types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options Liquid media option ...

Page 2

... Vdc supply 5.0 Vdc supply 4 Compensated temperature range 5 Operating temperature range Startup time (power up to data ready) Response time Upper output clipping limit Lower output clipping limit 6 Accuracy 7 Total error band Output resolution 2 www.honeywell.com/sensing Industrial Min. -0.3 -0.3 3 -40 [-40] Min. ...

Page 3

... Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. (See Figure 1 for ranges.) 9. Life may vary depending on specific application in which sensor is utilized. 10. Contact Honeywell Customer Service for detailed material information. CAUTION PRODUCT DAMAGE Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids. ...

Page 4

... Contact Honeywell Customer Service for more information. 2 12. Digital outputs (SPI are also available. Contact Honeywell Customer Service for more information. 13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information. 14. See Table 5 for an explanation of sensor pressure types. 15. See CAUTION on previous page. 4 www ...

Page 5

... Honeywell Sensing and Control Port 2) Long-term Stability (1000 hr, 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.35% FSS ...

Page 6

... Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance. Table 8. Pinout for DIP and SMT Packages Output Type Pin 1 analog NC Table 9. Pinout for SIP Packages Output Type Pin 1 analog NC 6 www.honeywell.com/sensing Over- 16 pressure P max. Absolute 1 bar 2 bar 1.6 bar 4 bar 2.5 bar 6 bar ...

Page 7

... DIA [0.076] 6,99 PORT 1 PORT 2 [0.275] PORT 1 9, [0.364] 2,54 TYP. 11,21 [0.100] [0.441] 3,78 [0.149] 8X 0,46 [0.018] Honeywell Sensing and Control 10,0 [0.39] 13,35 [0.525] 4,2 [0.17] 1,93 DIA. [0.076] 10,0 [0.39] 13,35 [0.525] 7 ...

Page 8

... PORT 1 [0.525] PORT 1 PORT 2 PORT 4,80 2,54 TYP. [0.189] [0.100] 6,77 [0.266] 3,78 [0.149] 8 www.honeywell.com/sensing SMT AN: Single axial barbed port 10,0 [0.39 13,4 6,99 [0.53] [0.275 [0.018] SMT RN: Single radial barbed port 10,0 [0.394] 13,35 6,99 [0.525] PORT 1 [0 ...

Page 9

... DIA. [0.097] 15,2 [0.60 0,25 4X 0,51 [0.010] [0.020] 17,78 [0.700] PORT 1 2X 4,78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] 17,78 [0.700] PORT 1 4.78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] Honeywell Sensing and Control 2,54 TYP. [0.100] 2,54 TYP. [0.100] 9 ...

Page 10

... SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 21,60 [0.850 SIP RN: Single radial barbed port SIP RR: Dual radial barbed ports, same side 10 www.honeywell.com/sensing 16,51 [0.650] PORT 2 PORT 1 2X 3,94 DIA. [0.155] 0,25 4X 0,51 [0.010] [0.020] 25,3 [0.996] PORT ...

Page 11

... PORT 2 PORT 1 PORT 0,25 2,54 TYP. 4X 0,51 [0.010] [0.100] [0.020] 5,36 [0.211] PORT 1 15,24 DIA. [0.600] 12,5 [0.49 0,25 [0.010] 4X 0,51 [0.100] [0.020] PORT 2,54 TYP. [0.100] Honeywell Sensing and Control PORT 1 28,96 [1.140] 11,27 [0.444 2,54 TYP. 11 ...

Page 12

... In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing ...

Related keywords