HSCSFFN005PDAA5 Honeywell, HSCSFFN005PDAA5 Datasheet - Page 12

no-image

HSCSFFN005PDAA5

Manufacturer Part Number
HSCSFFN005PDAA5
Description
Board Mount Pressure Sensors 5V AXIAL PORT 5psi DIFFER SIP
Manufacturer
Honeywell
Datasheet

Specifications of HSCSFFN005PDAA5

Operating Pressure
+/- 5 psi
Pressure Type
Differential
Accuracy
+/- 0.25 %
Output Type
Analog - Voltage
Mounting Style
Through Hole
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
2 mA
Package / Case
SIP-4
Digital Output - Bus Interface
Analog Voltage
Digital Output - Number Of Bits
12
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARNING
008216-2-EN IL50 GLO Printed in USA
March 2011
© 2011 Honeywell International Inc.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
Europe
Latin America
USA/Canada
Failure to comply with these instructions could result in
death or serious injury.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
WARNING
+65 6355-2828; +65 6445-3033 Fax
+44 (0) 1698 481481; +44 (0) 1698 481676 Fax
+1-305-805-8188; +1-305-883-8257 Fax
+1-800-537-6945; +1-815-235-6847
+1-815-235-6545 Fax