NLP65-9915J Emerson Network Power, NLP65-9915J Datasheet

POWER SUPPLY 15V 65W 4.4A 3X5"

NLP65-9915J

Manufacturer Part Number
NLP65-9915J
Description
POWER SUPPLY 15V 65W 4.4A 3X5"
Manufacturer
Emerson Network Power
Series
NLP65r
Datasheet

Specifications of NLP65-9915J

Operating Temperature
0°C ~ 70°C
Power (watts) - Rated
65W
Efficiency
72%
Approvals
CSA, UL, VDE
Line Regulation
±2%
Load Regulation
±2%
Voltage - Output
15V
Number Of Outputs
1
Power (watts)
65W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 4.4A
Size / Dimension
5" L x 3" W x 1.26" H (127mm x 76.2mm x 32mm)
Product
Switching
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1486
NLP65-9915J

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NLP65-9915J
Manufacturer:
BOURNS
Quantity:
30 000
• VDE0705/EN60601-1/IEC1010
• UL1950 File No. E147937
• CSA C22.2 No. 950
Special Features
• 85 VAC to 264 VAC universal
• Harmonic current correction
• Maximum component height
• UL, CSA and VDE safety approvals
• Overvoltage and short circuit
• 5 x 3 x 1.26 inch (127.0 x 76.2 x
• Available RoHS compliant
• 2 year warranty
Safety
NLP65 Medical
Series
Single, Dual and Triple output
Total Power:
Input Voltage: 85 - 264 VAC
# of Outputs:
File No. 10401-3336-0156/32480
Licence No. 121949
File No. LR41062C
input range
as standard
1.26 inches
protection
32mm) footprint
65 W
Single, Dual,
Triple
Input
Output
Electrical Specifications
Input voltage range:
Input frequency range:
Input current:
(cold start)
Safety ground leakage current:
Input current:
Input fuse:
Output power:
Total regulation:
(line and load)
Rise time:
Transient response:
Temperature coefficient:
Overvoltage protection:
Short circuit protection:
Universal input
(see Note 2)
120 Vac
230 Vac
264 Vac, 60 Hz
120 Vac
230 Vac
Natural convection
At turn-on
Main output
25% step at 0.1 A/µs
Main outputs
Cyclic operation
Embedded Power for
Business-Critical Continuity
85 - 264 Vac
47 - 63 Hz
17 A max.
32 A max
95 µA
1.05 A rms
0.51 A rms
250 Vac F 3.15 A
65 W max.
See table
1.0 s, max
5.0% max. dev.,
1ms recovery to 1.0%
± 0.02%/°C
125%, ± 10%
Yes
Rev.02.25.11_104
NLP65 Medical
1 of 4

Related parts for NLP65-9915J

NLP65-9915J Summary of contents

Page 1

... Transient response: Main output 25% step at 0.1 A/µs Temperature coefficient: Overvoltage protection: Main outputs Short circuit protection: Cyclic operation Embedded Power for Business-Critical Continuity Rev.02.25.11_104 NLP65 Medical 264 Vac max max 95 µA 1.05 A rms 0.51 A rms 250 Vac F 3. max. See table 1 ...

Page 2

... W 65W Derate to 50% load See table 5 to 95% RH 10,000 feet max. 30,000 feet max. 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 2.4 G rms approx. 516.4 Part IV Embedded Power for Business-Critical Continuity Rev.02.25.11_104 NLP65 Medical NATURAL 38W CONVECTION 32W COOLING ...

Page 3

... A 150 mV ±2.0% 3.5 A 240 mV ±2.0% ° ° +40 C. The ripple and regulation specifications may not be met. C, and no semiconductor case temperature should exceed 130 o Embedded Power for Business-Critical Continuity (11, 12) NLP65-9908J NLP65-9920J NLP65-9929J NLP65-9912J NLP65-9915J NLP65-9924J Rev.02.25.11_104 NLP65 Medical ...

Page 4

... Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and ser- vice marks of Emerson Electric Co. ©2011 Emerson Electric Co. Rev.02.25.11_104 NLP65 Medical ...