DS1050-3 Emerson Network Power, DS1050-3 Datasheet - Page 2

no-image

DS1050-3

Manufacturer Part Number
DS1050-3
Description
PWR SUP 12V 1050W 1U X 2U X 11"
Manufacturer
Emerson Network Power
Series
DS1050r
Datasheet

Specifications of DS1050-3

Operating Temperature
-10°C ~ 50°C
Power (watts) - Rated
1044W
Efficiency
92%
Approvals
CCC, CE, cUL, EN60950, NEMKO, UL
Line Regulation
5%
Load Regulation
5%
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1050W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Rack Mount
1st Output
12 VDC @ 87A
Size / Dimension
11.00" L x 3.20" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
279.4mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1429
Environmental Specifications
Logic Control
Ordering Information
*Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery.
** 3.3V standby can operate at 6A, but overall unit efficiency will fall slightly below Gold Standard.
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic susceptibility / Input transients:
RoHS & lead-free compliant:
Humidity:
Shock and vibration specificatons:
MTBF (Demonstrated):
PS_SEATED (A4):
PWR GOOD (C3):
AC OK (B1):
PS_INHIBIT/PS_KILL (B4):
PS ON (A1):
Model Number
DS1050-3-001
DS1050-3-002
DS1050-3-003
DS1050-3
Voltage Set Point
Nominal Output
12.0 Vdc
12.0 Vdc
12.0 Vdc
12.0 Vdc
TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if
the PSU is removed
A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS
early warning signal before 12.0 V DC output loss of regulation.
This signal is connected to a short pin on the PSU
When left open power supply operation will be inhibited. When the power supply is
inserted into the system, this pin will be pull low by the system and turn the power supply on only
after all other power supply pins have seated.
The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin
is driven high or left open.
Active TTL high when output is within regulation limits.
Tolerance
Set Point
±0.2%
±0.2%
±0.2%
±0.2%
Regulation
Total
±5%
±5%
±5%
±5%
Minimum
Current
-10° to 50 °C ; 50% power derating at 70 °C
-40 °C to +85 °C
10,000 ft
-EN61000-3-2, -3-3
-EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
No tantalum caps.
20 to 90% RH, non-condensing
Complies with Astec Std. Specifications, Q3205
500K Hrs at full load, 40 °C
0 A
0 A
0 A
0 A
Maximum
Current
87 A
87 A
87 A
87 A
Output Ripple
120 mV
120 mV
120 mV
120 mV
P/P
102.7 A - 128.4 A
102.7 A - 128.4 A
102.7 A - 128.4 A
102.7 A - 128.4 A
Over Current
Embedded Power for
Business-Critical Continuity
5.0 V @ 2.5 A
5.0 V @ 2.5 A
Stand-by**
3.3 V @ 4 A
3.3 V @ 4 A
Rev. 04.21.11_54
Air Flow
STD
REV
STD
REV
DS1050
2 of 4

Related parts for DS1050-3