E6C2-CWZ6C 200P/R 2M Omron, E6C2-CWZ6C 200P/R 2M Datasheet - Page 2

no-image

E6C2-CWZ6C 200P/R 2M

Manufacturer Part Number
E6C2-CWZ6C 200P/R 2M
Description
ENCODER ROTARY 5-24V 200RESOL 2M
Manufacturer
Omron
Series
E6C2r

Specifications of E6C2-CWZ6C 200P/R 2M

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
200
Voltage - Supply
5 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Vertical
Termination Style
Cable Leads
Product
Mechanical
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6C2-CWZ6C200P/R2M
E6C2CWZ6C200PR2M
Specifications
J RATINGS/CHARACTERISTICS
Electrical
Note: 1. An inrush current of approx. 9 A flows for approx. 0.3 ms right after the E6C2-C is turned on.
E6C2-C
Item
Power supply voltage
Current consumption
(See Note 1.)
Resolution
Output phases
Output configuration
Output capacity
Max. response
frequency
(See Note 3.)
Phase difference on
output
Rise and fall times of
output
Insulation resistance
Dielectric strength
2. The line driver output of the E6C2-C is used for data transmission circuitry conforming to RS-422A and ensures long-distance
3. The maximum electrical response revolution is determined by the resolution and maximum response frequency as follows:
transmission over twisted-pair cable, with quality equivalent to AM26LS31.
Maximum electrical response frequency (rpm) = maximum response frequency/resolution x 60
This means that the E6C2-C Rotary Encoder will not operate electrically if its revolution exceeds the maximum electrical
response revolution.
E6C2-CWZ6C
5 to 24 VDC (allowable
range: 4.75 to 27.6 VDC)
80 mA max.
10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 1,000, 1,200, 1,500,
1,800, 2,000 P/R
A, B, and Z (reversible)
NPN open collector
output
Applied voltage:
30 VDC max.
I
Residual voltage:
0.4 V max.
(I
100 kHz
90°±45° between A and B (1/4T±1/8T)
1 µs max.
(control output voltage: 5 V;
load resistance: 1 kΩ;
cable length: 2 m)
100 MΩ min. (at 500 VDC) between carry parts and case
500 VAC, 50/60 Hz for 1 min between carry parts and case
sink
sink
: 35 mA max.
: 35 mA max.)
E6C2-CWZ3E
5 to 12 VDC (allowable
range: 4.75 to 13.2 VDC)
100 mA max.
Voltage output (NPN
output)
Output resistance: 2 kΩ
(residual voltage:
0.4 V max.
I
1 µs max.
(cable length: 2 m;
I
sink
sink
: 20 mA max.)
: 10 mA max.)
3
E6C2-CWZ1X
5 VDC±5%
160 mA max.
A, A, B, B, Z, Z
Line driver (See Note 2.)
AM26LS31
Output current:
High level (I
Low level (I
Output voltage:
V
V
0.1 µs max.
(cable length: 2 m;
I
I
o
s
o
s
: - -20 mA;
: 20 mA)
: 2.5 V min.
: 0.5 V max.
s
o
): 20 mA
): - -20 mA
E6C2-CWZ5B
12 VDC - -10% to 24 VDC
+15%
100 mA max.
100, 200, 360, 500, 600,
1,000, 2,000 P/R
A, B, and Z (reversible)
PNP open collector
output
I
Residual voltage:
0.4 V max.
(I
50 kHz
1 µs max.
(cable length: 2 m;
I
sink
sink
sink
: 35 mA max.
: 10 mA max.)
: 35 mA max.)
E6C2-C