M29W400DB45N6E NUMONYX, M29W400DB45N6E Datasheet - Page 19

no-image

M29W400DB45N6E

Manufacturer Part Number
M29W400DB45N6E
Description
MEMORY, FLASH, NOR, 4MB, B/B, 48TSOP
Manufacturer
NUMONYX
Datasheet

Specifications of M29W400DB45N6E

Memory Size
4Mbit
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
No. Of Pins
48
Operating Temperature Range
-40°C To +85°C
Package / Case
TSOP
Access Time
45ns
Memory
RoHS Compliant
Memory Type
Flash - Boot Block
Memory Configuration
512K X 8, 256K X 16
Interface Type
Parallel
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W400DB45N6E
Manufacturer:
ST
0
4
4.1
4.2
4.3
Command interface
All Bus Write operations to the memory are interpreted by the command interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode. See either
used, for a summary of the commands.
Read/Reset command
The Read/Reset command returns the memory to its Read mode where it behaves like a
ROM or EPROM, unless otherwise stated. It also resets the errors in the Status Register.
Either one or three Bus Write operations can be used to issue the Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to Read mode. Once the program or erase
operation has started the Read/Reset command is no longer accepted. The Read/Reset
command will not abort an Erase operation when issued while in Erase Suspend.
Auto Select command
The Auto Select command is used to read the manufacturer code, the device code and the
Block Protection status. Three consecutive Bus Write operations are required to issue the
Auto Select command. Once the Auto Select command is issued the memory remains in
Auto Select mode until another command is issued.
From the Auto Select mode the manufacturer code can be read using a Bus Read operation
with A0 = V
manufacturer code for Numonyx is 0020h.
The device code can be read using a Bus Read operation with A0 = V
other address bits may be set to either V
00EEh and for the M29W400DB is 00EFh.
The Block Protection status of each block can be read using a Bus Read operation with
A0 = V
may be set to either V
Data inputs/outputs DQ0-DQ7, otherwise 00h is output.
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four Bus Write operations, the final write operation
latches the address and data and starts the Program/Erase controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
IL
, A1 = V
IL
and A1 = V
IH
, and A12-A17 specifying the address of the block. The other address bits
IL
or V
IL
. The other address bits may be set to either V
Table
IH
. If the addressed block is protected then 01h is output on
5, or
Table
IL
or V
6, depending on the configuration that is being
IH
. The device code for the M29W400DT is
IH
and A1 = V
IL
or V
IH
. The
IL
. The
19/48