MY2N 220/240ACS Omron, MY2N 220/240ACS Datasheet - Page 4

RELAY, DPCO, 220VAC

MY2N 220/240ACS

Manufacturer Part Number
MY2N 220/240ACS
Description
RELAY, DPCO, 220VAC
Manufacturer
Omron
Datasheet

Specifications of MY2N 220/240ACS

Relay Type
General Purpose
Coil Voltage Vac Nom
240V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
18.79kohm
Coil Type
AC Coil
Coil Current
5.3mA
Nom
RoHS Compliant
Contact Configuration
DPCO
Rohs Compliant
Yes
MY
High-sensitivity Relays
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of +15%/–20% for rated currents
*Note: P level:
Note: The values given above are initial values.
4
24 VDC
Item
Rated load
Carry
current
Max.
switching
voltage
Max.
switching
current
Max.
switching
capacity
Min.
permissible
load*
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Ambient operating temperature*
Ambient operating humidity
Weight
Contact Ratings
Characteristics
Voltage
2. Performance characteristic data are measured at a coil temperatures of 23 C.
3. The must operate and must release voltages for High-sensitivity Relays was measured at the rated power supply voltage.
4. AC coil resistance and impedance are provided as reference values (at 60 Hz).
5. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
and 15% for DC coil resistance.
resistor if required.
36.9 mA
5 A, 220 VAC
5 A, 24 VDC
5 A
250 VAC
125 VDC
5 A
1,100 VA
120 W
Standard type: 100 mA, 5 VDC
Bifurcated type: 100 A, 1 VDC
60
Item
Resistive load
Current
= 0.1 x 10
Single-, double- or three-pole
(cosf = 1)
Power supply ratings
-6
650 W
/operation, reference value
resistance
Coil
2 A, 220 VAC
2 A, 24 VDC
5 A
440 VA
48 W
Inductive load
(cosf=0.4,
L/R=7 ms)
50 m max.
20 ms max.
20 ms max.
Mechanical: 18,000 operations/hr
Electrical:
1,000 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
Destruction: 10 to 55 Hz, 1.0-mm double amplitude
Malfunction: 10 to 55 Hz, 1.0-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 200 m/s
See following table.
Single- and double-pole standard, bifurcated-contact, test-button, and high-humidity relays:
–55 C to 70 C (with no icing)
All other relays: –55 C to 60 C (with no icing)
35% to 85%
Approx. 85 g
All relays but High-sensitivity Relays
110%
voltage*
Max.
1,800 operations/hr (under rated load)
3 A, 220 VAC
3 A, 24 VDC
3 A
250 VAC
125 VDC
3 A
660 VA
72 W
Standard and high sensitivity types: 1
mA, 1 VDC
Bifurcated type: 100 A, 1 VDC
Resistive load
Four-pole and High-sensitivity
(cosf = 1)
Approx. 900 mW
Power consum.
2
(approx. 20G)
2
(approx. 100G)
0.8 A, 220 VAC)
1.5 A, 24 VDC
3 A
176 VA
36 W
Inductive load
2 to 12 V
(cosf=0.4,
L/R=7 ms)
voltage
Input
1,500 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
% of rated voltage
2 V max.
operate
7 A, 220 VAC
7 A, 24 VDC
7 A
250 VAC
125 VDC
7 A
1,540 VA
168 W
–––
Must
Resistive load
High-sensitivity Relays
Input ratings
(cosf = 1)
1 V min.
High-capacity
release
Must
3.5 A, 220 VAC
3.5 A, 24 VDC
7 A
770 VA
84 W
Inductive load
(cosf=0.4,
L/R=7 ms)
0.5 to 52 mW
consum.
Power
MY