G2R-1-T 12VDC Omron, G2R-1-T 12VDC Datasheet - Page 4

Power Relay

G2R-1-T 12VDC

Manufacturer Part Number
G2R-1-T 12VDC
Description
Power Relay
Manufacturer
Omron
Datasheet

Specifications of G2R-1-T 12VDC

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
275ohm
Contact Configuration
SPDT
Coil Current
43.6mA
Coil Type
DC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G2R
Note: Rated voltage of bifurcated crossbar contact type: 12 VDC, 24 VDC
High-sensitivity Relays
*Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of
Double-winding Latching Relays
*Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of 10%.
4
Rated voltage
Rated current* (50/60 Hz)
Coil resistance*
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current (50/60 Hz)
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Set coil
Reset coil
Must set voltage
Must reset voltage
Max. voltage
Power consumption
2. LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be in-
3. Operating characteristics are measured at a coil temperature of 23 C.
2. Operating characteristics are measured at a coil temperature of 23 C.
creased by approximately 1 mA; the VDC rated current, by approximately 4 mA.
10% (DC coil resistance).
Rated current*
Coil resistance*
Coil inductance
(H) (ref. value)
Rated current
Coil resistance
Coil inductance
(H) (ref. value)
Armature OFF 0.20
Armature ON
Armature OFF 0.37
Armature ON
Armature OFF
Armature ON
Armature OFF
Armature ON
5 VDC
106 mA
47
0.39
70% min. of rated voltage
15% min. of rated voltage
110% of rated voltage
Approx. 0.53 W
5 VDC
71.4 mA
70
0.75
70% max. of rated voltage
15% max. of rated voltage
110% of rated voltage
Approx. 0.36 W
6 VDC
88.2 mA
68
0.28
0.55
5 VDC
167 mA
30
0.073
0.146
119 mA
42
0.003
0.006
70% of rated voltage
70% of rated voltage
110% of rated voltage
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW
6 VDC
60 mA
100
0.53
1.07
12 VDC
43.6 mA
275
1.15
2.29
6 VDC
138 mA
43.5
0.104
0.208
100 mA
60
0.005
0.009
12 VDC
30 mA
400
2.14
4.27
24 VDC
21.8 mA
1,100
4.27
8.55
12 VDC
70.6 mA
170
0.42
0.83
50 mA
240
0.018
0.036
24 VDC
15 mA
1,600
7.80
15.60
48 VDC
11.5 mA
4,170
13.86
27.71
+15%
/
-20%
(AC rated current) or
24 VDC
34.6 mA
694
1.74
3.43
25 mA
960
0.079
0.148
48 VDC
7.5 mA
6,400
31.20
62.40
100 VDC
5.3 mA
18,860
67.2
93.2
G2R

Related parts for G2R-1-T 12VDC